[1]戴 煌,秦永文,萧 毅.320排动态容积CT冠状动脉成像诊断冠心病的初步应用[J].介入放射学杂志,2012,(07):541-546.
 DAI Huang,QIN Yong- wen,XIAO Yi.. Preliminary application of 320-detector row dynamic volume CT angiography in diagnosing coronary heart diseases[J].journal interventional radiology,2012,(07):541-546.
点击复制

320排动态容积CT冠状动脉成像诊断冠心病的初步应用 ()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2012年07期
页码:
541-546
栏目:
心脏介入
出版日期:
2012-07-30

文章信息/Info

Title:
 Preliminary application of 320-detector row dynamic volume CT angiography in diagnosing coronary heart diseases
作者:
 戴 煌 秦永文 萧 毅
Author(s):
 DAI Huang QIN Yong- wen XIAO Yi.
 Department of Cardiology, the Affiliated Changhai Hospital, Second Military Medical University, Shanghai 200433, China
关键词:
 【关键词】 冠心病冠状血管造影 320排动态容积CT
文献标志码:
A
摘要:
 【摘要】 目的 探讨320排动态容积CT冠状动脉成像(CTA)诊断冠心病的准确性。 方法 2010年3月至2010年9月对临床拟诊为冠心病的82例患者先后行冠状动脉CTA及冠状动脉造影(ICA)检查,并以ICA为金标准,评估320排CTA诊断冠状动脉狭窄≥ 50%及≥ 70%的敏感度、特异度、阳性预测值及阴性预测值。 结果 CTA成像质量4分71例(86.6%),平均心率为67次/min;3分10例(12.2%),平均心率为74次/min;2分1例(1.2%),心率为83次/min;1分0例,全部病例均无阶梯伪影。CTA发现174个狭窄≥ 50%的节段,ICA发现144个。以ICA为金标准,320排CTA诊断狭窄≥50%的敏感度、特异度、阳性预测值及阴性预测值分别为93.1%、96.0%、77.0%和99.0%。CTA发现40个狭窄≥ 70%的节段,ICA发现40个。以ICA为金标准,320排CTA诊断狭窄≥ 70%的敏感度、特异度、阳性预测值及阴性预测值分别为100%、95.6%、45.5%和100%。 结论 320排CTA图像质量好,诊断冠心病准确可靠。

参考文献/References:

[1]   Miller JM, Rochitte CE, Dewey M, et al. Diagnostic perform?蛳ance of coronary angiography by 64?蛳 row CT[J]. N Engl J Med, 2008, 359: 2324 ?蛳 2336.
[2]   Frank J, Rybicki, Hansel J, et al. Initial evaluation of coronary images from 320?蛳 detector row computed tomography[J]. Int J Cardiovasc Imaging, 2008, 24: 535 ?蛳 546.
[3]   Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association[J]. Circulation, 1975, 51: 5 ?蛳 40.
[4]   Roberts WT, Bax JJ, Davies LC. Cardiac CT and CT coronary angiography: technology and application[J]. Heart, 2008, 94: 781?蛳 792.
[5]  Mark DB, Berman DS, Budoff MJ, et al. ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 expert consensus document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents[J]. Circulation, 2010, 76: E1 ?蛳 42.
[6]  Salavati A, Radmanesh F, Heidari K, et al. Dual?蛳 source computed tomography angiography for diagnosis and assessment of coronary artery disease: Systematic review and meta?蛳 analysis[J]. J Cardiovasc Comput Tomogr, 2012, 6: 78 ?蛳 90.
[7]   Dewey M, Zimmermann E, Deissenrieder F, et al. Noninvasive coronary angiography by 320?蛳 row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head?蛳 to?蛳head pilot investigation[J]. Circulation, 2009, 120: 867 ?蛳 875.
[8]   Nasis A, Leung MC, Antonis PR, et al. Diagnostic accuracy of noninvasive coronary angiography with 320?蛳 detector row comp?蛳uted tomography[J]. Am J Cardiol, 2010, 106: 1429 ?蛳 1435.
[9]  de Graaf FR, Schuijf JD, van Velzen JE, et al. Diagnostic accuracy of 320?蛳 row multidetector computed tomography corona?蛳ry angiography in the non?蛳 invasive evaluation of significant cor?蛳onary artery disease[J]. Eur Heart J, 2010, 31: 1908 ?蛳 1915.
[10]  Khan A, Khosa F, Nasir K, et al. Comparison of radiation dose and image quality: 320?蛳MDCT versus 64?蛳 MDCT coronary ang?蛳iography[J]. Am J Roentgenol, 2011, 197: 163 ?蛳 168.
[11] Rybicki FJ, Otero HJ, Steigner ML, et al. Initial evaluation of coronary images from 320?蛳 detector row computed tomography[J]. Int J Cardiovasc Imaging, 2008, 24: 535 ?蛳 546.
[12]  Gang S, Min L, Li L, et al. Evaluation of CT coronary artery angiography with 320?蛳 row detector CT in a high?蛳 risk population[J]. Br J Radiol, 2011,85: 562 ?蛳 570
[13]  Ropers D, Rixe J, Anders K, et al. Usefulness of multidetector row spiral computed tomography with 64?蛳 x 0.6?蛳 mm collimation and 330?蛳 ms rotation for the noninvasive detection of significant coronary artery stenoses[J]. Am J Cardiol, 2006, 97: 343 ?蛳 348.
[14]  Nikolaou K, Knez A, Rist C, et al. Accuracy of 64?蛳 MDCT in the diagnosis of ischemic heart disease[J]. Am J Roentgenol, 2006, 187: 111 ?蛳 17.
[15]  Ehara M, Surmely JF, Kawai M, et al. Diagnostic accuracy of 64?蛳 slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography[J]. Circ J, 2006, 70: 564 ?蛳 571.
[16]  Raff GL, Gallagher MJ, O’neill WW, et al. Diagnostic accuracy of non?蛳 invasive coronary angiography using 64?蛳 slice spiral com?蛳puted tomography[J]. J Am Coll Cardiol, 2005, 46: 552 ?蛳 557.
[17] Lee AB, Nandurkar D, Schneider-Kolsky ME, et al. Coronary image quality of 320?蛳 MDCT in patients with heart rates above 65 beats per minute: preliminary experience[J]. Am J Roentgenol, 2011, 196: W729?蛳 W735.
[18] Uehara M, Funabashi N, Ueda M, et al. Quality of coronary arterial 320?蛳 slice computed tomography images in subjects with chronic atrial fibrillation compared with normal sinus rhythm[J]. Int J Cardiol, 2011, 150: 65 ?蛳 70.
[19] Miller LM, Rochitte CE, Dewey M, et al. Diagnostic perform?蛳ance of coronary angiography by 64?蛳 row CT[J]. N Engl J Med, 2008, 359: 2324 ?蛳 2336.
[20]  覃   杰, 刘凌云, 董云旭, 等. 320排CT前瞻性和回顾性心电门控冠状动脉成像: 放射剂量、图像质量及诊断结果的对照观察[J]. 中国医学影像技术, 2010, 26: 951 ?蛳 954.
[21]  Khan A, Khosa F, Nasir K, et al. Comparison of radiation dose and image quality: 320?蛳 MDCT versus 64?蛳 MDCT coronary angiography[J]. Am J Roentgenol, 2011, 197: 163 ?蛳 168.
[22] Leber AW, Becker A, Knez A, et al. Accuracy of 64?蛳 slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound[J]. J Am Coll Cardiol, 2006, 47: 672 ?蛳 677.
[23] Miller JM, Rochitte CE, Dewey M, et al. Diagnostic perform?蛳ance of coronary angiography by 64?蛳 row CT[J]. N Engl J Med, 2008, 359: 2324 ?蛳 2336.
[24] Rybicki FJ, Melchionna S, Mitsouras D, et al. Prediction of coronary artery plaque progression and potential rupture from 320?蛳detector row prospectively ECG?蛳 gated single heart beat CT angiography:Lattice Boltzmann evaluation of endothelial shear stress[J]. Int J Cardiovasc Imaging, 2009, 25: 289 ?蛳 299.

相似文献/References:

[1]张 琳,黄学全,王健,等.自主研发电化学治疗同轴电极与传统针式电极电解效应的对比研究[J].介入放射学杂志,2012,(02):148.
 ZHANG Lin,HUANG Xue-quan,WANG Jian,et al.The electrolytic effect in electrochemotherapy: a comparative study between self-prepared coaxial electrode and conventional needle electrode[J].journal interventional radiology,2012,(07):148.
[2]赵 玮,王伟中,陈莹,等.耳部动静脉畸形供血动脉的血管造影研究[J].介入放射学杂志,2012,(02):103.
 ZHAO Wei,WANG Wei-zhong,CHEN Ying,et al.Angiographic findings of the feeding arteries of auricular arteriovenous malformations[J].journal interventional radiology,2012,(07):103.
[3]邹俊民,龙世娟,张振明. 改良髂内动脉化疗联合放疗治疗Ⅲ~Ⅳa期 子宫颈癌32例[J].介入放射学杂志,2012,(02):123.
 ZOU Jun-min,LONG Shi-Juan,ZHANG Zheng-ming..Improved internal iliac artery chemotherapy combined with radiotherapy for the treatment of stage Ⅲ-Ⅳa cervical cancers[J].journal interventional radiology,2012,(07):123.
[4]王昌明,李 选,宋世兵,等.肝门部胆道引流管折叠技术在肝移植后胆道非吻合口狭窄治疗中的应用[J].介入放射学杂志,2012,(02):136.
 WANG Chang-ming,LI Xuan,SONG Shi-bing,et al.The application of biliary catheter folding technique in the treatment of hilar nonanastomotic biliary strictures after orthotopic liver transplantation[J].journal interventional radiology,2012,(07):136.
[5]赵玉峰,孙玉琴,韩晓静,等. 输卵管介入再通术后受孕时机的研究[J].介入放射学杂志,2012,(02):158.
 ZHAO Yu-feng,SUN Yu-qin,HAN Xiao-jing,et al.The optimal time for conception after fallopian tube recanalization therapy[J].journal interventional radiology,2012,(07):158.
[6]含 笑,曹建民,史东宏,等.吉西他滨、顺铂动静脉联合化疗治疗晚期非小细胞肺癌的近期疗效分析[J].介入放射学杂志,2012,(02):119.
 HAN Xiao,CAO Jian-min,SHI Dong-hong,et al.Bronchial artery infusion of Gemcitabine and Cisplatin combined with systemic chemotherapy for advanced non-small cell lung cancer: its short-term efficacy[J].journal interventional radiology,2012,(07):119.
[7]姚雪松,李 槐.不可手术切除的肝细胞癌的疗效评价标准——改良RECIST标准更可靠[J].介入放射学杂志,2012,(03):177.
 . Therapeutic evaluation criterion of inoperable hepatocellular carcinomas: modified RECIST as a more reliable standard[J].journal interventional radiology,2012,(07):177.
[8]齐 立,李慎茂,俸军林,等. 动脉溶栓与机械碎栓联合动脉溶栓的对比分析[J].介入放射学杂志,2012,(03):180.
 ,,et al. Comparison of the therapeutic efficacy between simple arterial thrombolysis and mechanical thrombectomy combined with arterial thrombolysis for acute cerebral infarction at its ultraearly stage[J].journal interventional radiology,2012,(07):180.
[9]石 潆,赵 卫,沈 进,等.脑动静脉畸形栓塞治疗术并发颅内出血的原因及处理[J].介入放射学杂志,2012,(03):185.
 ,,et al.Intracranial hemorrhage due to embolization therapy for cerebral arteriovenous malformation: its causes and management [J].journal interventional radiology,2012,(07):185.
[10]周 慷,李晓光,金征宇,等.清宫术前子宫动脉化疗栓塞术治疗瘢痕妊娠的疗效分析[J].介入放射学杂志,2012,(03):190.
 ,,et al.Therapeutic analysis of bilateral uterine artery chemoembolization performed before uterine dilation and curettage for cesarean scar pregnancy [J].journal interventional radiology,2012,(07):190.
[11]罗育坤,范 林,林朝贵,等. 破裂斑块行介入治疗对冠状动脉血流的影响[J].介入放射学杂志,2012,(11):898.
 LUO Yu-kun,FAN Lin,LIN Chao- gui,et al. Changes of coronary flow occurred after percutaneous coronary intervention for ruptured plaque detected by intravascular ultrasound[J].journal interventional radiology,2012,(07):898.
[12]潘静薇,陆志刚,张佳胤,等. 冠状动脉介入治疗后迟发型对比剂肾病[J].介入放射学杂志,2013,(01):15.
 PAN Jing? wei,LU Zhi? gang,ZHANG Jia? yin,et al. Delayed contrast?蛳 induced nephropathy occurring after percutaneous coronary intervention[J].journal interventional radiology,2013,(07):15.
[13]王智廷,曹国全,闻彩云,等. 冠状动脉介入治疗中操作者所受剂量的综合研究[J].介入放射学杂志,2013,(10):834.
 WANG Zhi? ting,CAO Guo? quan,WEN Cai? yun. HUANG Zhou? qing.. The radiation dose to operators in performing percutaneous coronary intervention: a comprehensive study[J].journal interventional radiology,2013,(07):834.

备注/Memo

备注/Memo:
 (收稿日期:2012-02-04)
更新日期/Last Update: