[1]卢维龙,王 兵,王 颖,等.新型蝶式股动脉压迫装置和人工压迫在外周动脉腔内治疗术后止血效果的对比 [J].介入放射学杂志,2019,28(03):288-292.
 LU Weilong,WANG Bing,WANG Ying,et al.A new butterfly femoral artery compression device vs manual compression for hemostasis of femoral artery puncture point after peripheral endovascular interventions[J].journal interventional radiology,2019,28(03):288-292.
点击复制

新型蝶式股动脉压迫装置和人工压迫在外周动脉腔内治疗术后止血效果的对比



()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
28
期数:
2019年03期
页码:
288-292
栏目:
临床研究
出版日期:
2019-03-25

文章信息/Info

Title:
A new butterfly femoral artery compression device vs manual compression for hemostasis of femoral artery puncture point after peripheral endovascular interventions
作者:
卢维龙 王 兵 王 颖 许 恒 潘锦轩 王梦宇 郭 鹏 王彦岭 尚文煊
Author(s):
LU Weilong WANG Bing WANG Ying XU Heng PAN Jinxuan WANG Mengyu GUO Peng WANG Yanling SHANG Wenxuan.
Department of Vascular Surgery, Fifth Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
关键词:
【关键词】 股动脉 止血 穿刺 并发症
文献标志码:
A
摘要:
【摘要】 目的 比较经股动脉穿刺行外周动脉腔内治疗术后新型蝶式股动脉压迫装置(femoral artery compression device,FACD)和人工压迫(manual compression,MC)止血的安全性和有效性。方法 收集2016年9月至2017年12月经股动脉穿刺行外周动脉腔内治疗术的患者283例,术后采用新型FACD(FACD组)止血167例,MC止血(MC组)116例。分析患者的舒适度、止血时间、肢体制动时间以及血管并发症的发生情况。结果 283例患者全部纳入分析,结果显示FACD组止血成功率96.4%(161/167),MC组止血成功率94.0%(109/116),两组差异无统计学意义(P>0.05)。与MC组比较,FACD组术后Kolcaba舒适量表评分明显增高(85.0±11.2比58.4±11.7,P<0.05),止血时间、肢体制动时间显著缩短分别为[(9.2±2.2) min比(18.5±2.9) min,(P<0.05);(10.4±2.4) h比(23.1±4.1) h,(P<0.05)],血管并发症发生率明显减少(3.6%比 9.5%, χ2=4.206,P=0.04)。结论 新型蝶式FACD用于股动脉穿刺后止血迅速、安全、有效,止血时间、肢体制动时间、患者舒适度以及血管并发症发生率等均优于人工压迫,值得在临床上推广。

参考文献/References:

[1] Fowkes FG, Rudan D, Rudan I, et al. Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: a systematic review and analysis[J]. Lancet, 2013, 382: 1329- 1340.
[2] 王冬清, 岳嘉宁, 符伟国. 周围动脉疾病相关指南解读[J]. 中国实用外科杂志, 2016, 36: 1278- 1281.
[3] Das R, Ahmed K, Athanasiou T, et al. Arterial closure devices versus manual compression for femoral haemostasis in interventional radiological procedures: a systematic review and meta- analysis[J]. Cardiovasc Intervent Radiol, 2011, 34: 723- 738.
[4] Cox T, Blair L, Huntington C, et al. Systematic review of randomized controlled trials comparing manual compression to vascular closure devices for diagnostic and therapeutic arterial procedures[J]. Surg Technol Int, 2015, 27: 32- 44.
[5] 刘 楠, 张广平, 李慎茂. 动脉压迫止血器在脑血管造影术后的应用[J]. 介入放射学杂志, 2012, 21: 593- 596.
[6] Wong SC, Bachinsky W, Cambier P, et al. A randomized comparison of a novel bioabsorbable vascular closure device versus manual compression in the achievement of hemostasis after percutaneous femoral procedures: the ECLIPSE(Ensure’s Vascular Closure Device Speeds Hemostasis Trial)[J]. JACC Cardiovasc Interv, 2009, 2: 785- 793.
[7] 李郁芳, 叶容臻, 刘 巍. 经股动脉介入术后穿刺点止血方法的现状和进展[J]. 介入放射学杂志, 2012, 21: 961- 965.
[8] Fokkema TM, Minnee RC, Kock GA, et al. Comparison of a collagen plug arterial closure device with manual compression after endovascular interventions for peripheral artery disease[J]. J Vasc Surg, 2016, 64: 104e1- 108e1.
[9] van der Steeg HJ, Berger P, Krasznai AG, et al. Acute arterial occlusion after deployment of the Angio- Seal closure device: is it as uncommon as we think?[J]. Eur J Vasc Endovasc Surg, 2009, 38: 715- 717.
[10] Siani A, Accrocca F, Gabrielli R, et al. Management of acute lower limb ischemia associated with the Angio- Seal arterial puncture closing device[J]. Interact Cardiovasc Thorac Surg, 2011, 12: 400- 403.
[11] Dregelid E, Jensen G, Daryapeyma A. Complications associated with the Angio- Seal arterial puncture closing device: intra- arterial deployment and occlusion by dissected plaque[J]. J Vasc Surg, 2006, 44: 1357- 1359.
[12] 卿洪琨, 张小明, 蒋京军, 等. 血管闭合器简介[J]. 介入放射学杂志, 2015, 24: 548- 552.

相似文献/References:

[1]黄献琛,倪才方.动脉穿刺止血方法的进展[J].介入放射学杂志,2011,(04):325.
 HUANG Xian-chen,NI Cai-fang..The technical progress in haemostasis of arterial puncture point[J].journal interventional radiology,2011,(03):325.
[2]陈 波,许 健,曹建民,等.兔血管造影的实验研究[J].介入放射学杂志,2011,(04):296.
 CHEN Bo,XU Jian,CAO Jian-min.Angiographic technique in rabbits: an experimental study[J].journal interventional radiology,2011,(03):296.
[3]周 勇,陈少萍,徐荣良,等.皮下8字缝合止血技术在结构性心脏病介入术中的应用[J].介入放射学杂志,2012,(12):984.
 ZHOU Yong,CHEN Shao? ping,XU Rong? liang,et al. The application of subcutaneous “Figure-of- Eight” suture hemostasis technique in interventional treatment of structural congenital heart diseases[J].journal interventional radiology,2012,(03):984.
[4]曹莉明,王 杰,施海彬,等.股动脉穿刺定位方法的优化研究 [J].介入放射学杂志,2013,(05):409.
 CAO Li? ming,WANG Jie,SHI Hai? bin,et al. Optimization of the location technique for puncturing site of common femoral artery[J].journal interventional radiology,2013,(03):409.
[5]杨卷红. 股动脉穿刺置管术后快速手法压迫止血的体会[J].介入放射学杂志,2013,(05):412.
 YANG Juan? hong.. Rapid manual compression for puncturing site hemostasis after femoral catheterization: preliminary experience[J].journal interventional radiology,2013,(03):412.
[6]梁刚柱,张福先,刘 勇. 辛伐他汀对兔股动脉球囊损伤后内膜增生和平滑肌细胞增殖的影响[J].介入放射学杂志,2014,(01):50.
 LIANG Gang? zhu,ZHANG Fu? xian,LIU Yong.. The effects of simvastatin on intimal hyperplasia and vascular smooth muscle cell proliferation of balloon?蛳 injured femoral artery in experimental rabbits[J].journal interventional radiology,2014,(03):50.
[7]李郁芳,叶容臻,刘 巍. 经股动脉介入术后穿刺点止血方法的现状和进展[J].介入放射学杂志,2012,(11):961.
 LI Yu? fang,YE Rong? zhen,LIU Wei.. Techniques for hemostasis of puncturing point after interventional management through femoral artery: its present situation and research progress[J].journal interventional radiology,2012,(03):961.
[8]郭俊,徐帝非,沈下贤,等.两类桡动脉压迫止血器临床应用效果分析[J].介入放射学杂志,2016,(07):577.
 effectGUO Jun,XU Di-fei,SHEN Xia-xian,et al.The application of two kinds of radial artery compression hemostasis device: analysis of their clinical[J].journal interventional radiology,2016,(03):577.
[9]刘玉龙,李承志,王晓白,等.ExoSeal血管封堵器在肱动脉高位穿刺点止血中的临床应用[J].介入放射学杂志,2020,29(06):560.
 LIU Yulong,LI Chengzhi,WANG Xiaobai,et al.Clinical application of ExoSeal vascular closure device in the hemostasis of“high position” puncture point of brachial artery[J].journal interventional radiology,2020,29(03):560.
[10]田文静,蔡平凡,王 莹,等.改良式腰托联合骨科患肢制动固定装置的设计及肝癌介入术后应用[J].介入放射学杂志,2021,30(06):621.
 TIAN Wenjing,CAI Pingfan,WANG Ying,et al.The design of improved lumbar support combined with orthopedic limb-immobilization device and its application in liver cancer patients after receiving interventional therapy[J].journal interventional radiology,2021,30(03):621.
[11]田 丰,贾中芝,王 凯,等.“威派”止血贴在股动脉穿刺点止血中的应用[J].介入放射学杂志,2012,(12):1028.
 TIAN Feng,JIA Zhong? zhi,WANG Kai,et al. The application of "V + Pad" point plaster in hemostasis of femoral artery puncturing point after interventional therapy[J].journal interventional radiology,2012,(03):1028.

备注/Memo

备注/Memo:
(收稿日期:2018-06-10)
(本文编辑:俞瑞纲)
更新日期/Last Update: 2019-03-20