参考文献/References:
[1] Molyneux A, Kerr R, Stratton I, et al. International Subarachnoid Aneurysm Trial(ISAT) of neurosurgical clipping versus endo- vascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial[J]. Lancet, 2002, 360: 1267- 1274.
[2] Raymond J, Guilbert F, Weill A, et al. Long- term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils[J]. Stroke, 2003, 34: 1398- 1403.
[3] Molyneux AJ, Kerr RS, Yu LM, et al. International Subarachnoid Aneurysm Trial(ISAT) of neurosurgical clipping versus endovas- cular coiling in 2143 patients with ruptured intracranial aneury- sms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion[J]. Lancet, 2005, 366: 809- 917.
[4] 李明华. 一种新型的脑动脉瘤血管内治疗技术——脑血管覆膜支架术的问世[J]. 介入放射学杂志, 2010, 19: 253- 256.
[5] 朱悦琦, 李明华, 谢 剑, 等. Willis覆膜支架治疗犬颈内动脉虹吸段动脉瘤的影像学和组织病理学研究[J]. 介入放射学杂志, 2010, 19: 302- 308.
[6] Lylyk P, Miranda C, Ceratto R, et al. Curative endovascular reconst- ruction of cerebral aneurysms with the pipeline embolization device: the buenos aires experience[J]. Neurosurgery, 2009, 64: 632- 642.
[7] D’urso PI, Lanzino G, Cloft HJ, et al. Flow diversion for intracranial aneurysms a review[J]. Stroke, 2011, 42: 2363- 2368.
[8] Mao L, Yuan GY, Niu JL, et al. In vitro degradation behavior and biocompatibility of Mg- Nd- Zn- Zr alloy by hydrofluoric acid treatment[J]. Mater Sci Eng C Mater Biol Appl, 2013, 33: 242- 250.
[9] Mao L, Yuan GY, Wang SH, et al. A novel biodegradable Mg- Nd- Zn- Zr alloy with uniform corrosion behavior in artificial plasma[J]. Mater Lett, 2012, 88: 1- 4.
[10] Zong Y, Yuan GY, Zhang XB, et al. Comparison of biodegradable behaviors of AZ31 and Mg- Nd- Zn- Zr alloys in Hank’s physiological solution[J]. Mater Sci Eng B, 2012, 177: 395- 401.
[11] 袁广银, 章晓波, 牛佳林, 等. 新型可降解生物医用镁合金JDBM 的研究进展[J]. 中国有色金属学报, 2011, 21: 2476- 2488.
[12] Li MH, Gao BL, Fang C, et al. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization[J]. Neuroradiology, 2006, 48: 907- 915.
[13] Im SH, Han MH, Kwon OK, et al. Endovascular coil embolization of 435 small asymptomatic unruptured intracranial aneurysms:procedural morbidity and patient outcome[J]. AJNR, 2009, 30: 79- 84.
[14] Li MH, Leng B, Li YD, et al. Comparative study of covered stent with coil embolization in the treatment of cranial internal carotid artery aneurysm: a nonrandomized prospective trial[J]. Eur Radiol, 2010, 20: 2732- 2739.
[15] Wang W, Li MH, Li YD, et al. Treatment of traumatic internal carotid artery pseudoaneurysms with the willis covered stent: a prospective study[J]. J Trauma, 2011, 70: 816- 822.
[16] Kirkland NT. Magnesium biomaterials: past, present and future[J]. Corr Eng Sci Tech, 2012, 47: 322- 328.
[17] Romani A. Regulation of magnesium homeostasis and transport in mammalian cells[J]. Arch Biochem Biophys, 2007, 458: 90- 102.
[18] Waksman R, Erbel R, Di Mario C, et al. Early- and long- term int- ravascular ultrasound and angiographic findings after bioabsor- bable magnesium stent implantation in human coronary arteries[J]. JACC Cardiovasc Interv, 2009, 2: 312- 320.
[19] Wittchow E, Adden N, Riedmuller J, et al. Bioresorbable drug- eluting magnesium- alloy scaffold: design and feasibility in a porcine coronary model[J]. Eur Interv, 2013, 8: 1441- 1450.
[20] Haude M, Erbel R, Erne P, et al. Safety and performance of the drug- eluting absorbable metal scaffold(DREAMS) in patients with de- novo coronary lesions: 12 month results of the prospective, multicentre, first- in- man BIOSOLVE- Ⅰtrial[J]. Lancet, 2013, 381: 836- 844.
相似文献/References:
[1]王 武,李明华,顾斌贤.Willis覆膜支架治疗难治性外伤性颈动脉海绵窦瘘[J].介入放射学杂志,2011,(03):177.
WANG Wu,LI Ming-hua,GU Bin-xian..Endovascular treatment of complex traumatic direct carotid-cavernous fistulas by using Willis covered stent[J].journal interventional radiology,2011,(02):177.
[2]阿西木江?阿西尔,苗 统,迪力木拉提?艾来提,等.Willis覆膜支架治疗颈内动脉血泡样动脉瘤疗效的Meta分析[J].介入放射学杂志,2023,32(04):313.
AXIMUJIANGAxier,MIAO Tong,DILIMULATIAilaiti,et al.Willis covered stent for the treatment of blood blister-like aneurysms of internal carotid artery: a meta-analysis[J].journal interventional radiology,2023,32(02):313.