参考文献/References:
[1]Wasnich RD.Vertebral fracture epidemiology[J].Bone,1996,18(3Suppl ):179S-183S.
[2]Trout AT,Kallmes DF.Does vertebroplasty cause incident vertebral fracture?A review of available data[J].AJNR,2006,27:1397-1403.
[3]Uppin AA,Hirsch JA,Centenera LV,et al.Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis[J].Radiology,2003,226:119-124.
[4]Kim SH,Kang HS ,Choi JA,et al.Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty[J].Acta Radiol,2004,45:440-445.
[5]Grados F,Depriester C,Cayrolle G,et al.Long-term obse rva-tions of vertebral osteoporotic fractures treated by percutaneous vertebroplasty[J].Rheumatology(Oxford),2000,39:1410-1414.
[6]Tanigawa N,Komemushi A,Kariya S,et al.Radiological follow-up of new compression fractures following percutaneous vertebroplasty[J].Cardiovasc Intervent Radiol,2006,29:92-96.
[7]Trout AT,Kallmes DF,Kaufmann TJ.New fractures after vertebroplasty:adjacent fractures occur significantly sooner[J].AJNR,2006,27:217-223.
[8]Voormolen MH,Lohle PN,Juttmann JR,et al.The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty[J].J Vasc Interv Radiol,2006,17:71-76
[9]Cortet B,Cotten A,Boutry N,et al.Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures:an open prospective study[J].J Rheumatol,1999,26:2222-2228.
[10]Diamond TH,Champion B,Clark WA.Management of acute osteoporotic vertebral fractures:a nonrandomized trial comparing percutaneous vertebroplasty with conservative therapy[J].Am JMed,2003,114:257-265.
[11]Do HM,Kim BS,Marcellus ML ,et al.Prospective analysis of clinical outcomes after percutaneous vertebroplasty for painful osteoporotic vertebral body fractures[J].AJNR,2005,26:1623-1628.
[12]Legroux-Gerot I,Lormeau C,Boutry N,et al.Long-term follow-up of vertebral osteoporotic fractures treated by percutaneous vertebroplasty[J].Clin Rheumatol,2004,23:310-317.
[13]Jensen ME,Dion JE.Percutaneous vertebroplasty in the treat-ment of osteoporotic compression fractures[J].Neuroimaging Clin N Am,2000,10:547-568.
[14]Lindsay R,Silverman SL,Cooper C,et al.Risk of new vertebral fracture in the year following a fracture[J].JAMA,2001,285:320-323.
[15]Ismail AA,Cooper C,Felsenberg D,et al.Number and type of vertebral deformities:epidemiological characteristics and relation to back pain and height loss[J].Eur Osteoporos Int ,1999,9:206-213.
[16]Laredo JD,Hamze B.Complications of percutaneous vertebro-plasty and their prevention[J].Skeletal Radiol,2004,33:493-505.
[17]Laredo JD,Hamze B.Complications of percutaneous vertebro-plasty and their prevention[J].Semin Ultrasound CT MR,2005,26:65-80.
[18]Berlemann U,Ferguson SJ,Nolte LP,et al.Adjacent vertebral failure after vertebroplasty.A biomechanical investigation[J].J Bone Joint Surg Br ,2002,84:748-752.
[19]Baroud G,Heini P,Nemes J,et al.Biomechanical explanation of adjacent fractures following vertebroplasty[J].Radiology,2003,229:606-607.
[20]Baroud G,Nemes J,Heini P,et al.Load shift of the interve-rtebral disc after a vertebroplasty:a finite-element study[J].Eur Spine J,2003,12:421-426.
[21]Polikeit A,Nolte LP,Ferguson SJ.The effect of cement aug-mentation on the load transfer in an osteoporotic functional spinal unit:finite-element analysis[J].Spine,2003,28:991-996.
[22]Ferguson S,Berlemann U,Heini PF,et a1.Evaluation of adja-cent segment failure following vertebroplasty[D].Precedings of the47th annaual meeting of the orthopaedic research society,San Francisco,2001,128-131.
[23]Farooq N,Park JC,Pollintine P,et al.Can vertebroplasty restore normal loadbearing to fractured vertebrae?[J]Spine,2005,30:1723-1730.
[24]Trout AT,Kallmes DF,Theilen KR,et al.Vertebral end plate fractures:an indicator of the abnormal forces generated in the spine following vertebroplasty[D].Paper presented at:American Society of Spine Radiology2005Annual Symposium;February24-27,2005;San Juan,Puerto Rico
[25]Palmer W,Suri R,Kattapuram S.Benign versus malignant verte bral collapse:value of a fracture line on MR images[J].Radiology,1999,213(Suppl P):293.
[26]Kaplan FS,Scherl JD,Wisneski R,et al.The cluster phenomenon in patients who have multiple vertebral compression fractures[J].Clin Orthop Relat Res,1993,297:161-167.
[27]Trout AT,Kallmes DF,Lane JI,et al.Subsequent vertebral fractures after vertebroplasty:association with intraosseus clefts[J].AJNR,2006,27:1586-1591.
[28]朱雪娥,吴春根,张继,等.椎体内裂隙样变对椎体成形术治疗椎体压缩骨折疗效的影响[J].介入放射学杂志,2008,17:102-105.
[29]Delmas PD,Genant HK,Crans GG,et al.Severity of prevalent vertebral fractures and the risk of subsequent vertebral and nonvertebral fractures:results from the MORE trial[J].Bone,2003,33:522-532.
[30]Komemushi A,Tanigawa N,Kariya S,et al.Percutaneous vertebroplasty for osteoporotic compression fracture:multivariate study of predictors of new vertebral body fracture[J].Cardiovasc Intervent Radiol,2006,29:580-585.
[31]Lin EP,Ekholm S,Hiwatashi A,et al.Vertebroplasty:cement leakage into the disc increases the risk of new fracture ofadjacent vertebral body[J].AJNR,2004,25:175-180.
[32]Syed MI ,Patel NA,Jan S,et al.Intradiskal extravasation with low-volume cement filling in percutaneous vertebroplasty[J].AJNR,2005,26:2397-2401.
[33]Lin EP,Ekholm S,Hiwatashi A,et al.Vertebroplasty:cement leakage into the disc increases the risk of new fracture of adjacent vertebral body[J].AJNR,2004,25:175-180.
[34]Liebschner MA,Rosenberg WS ,Keaveny TM.Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty[J].Spine,2001,26:1547-1554.
[35]Baroud G,Bohner M.Biomechanical impact of vertebroplasty.Postoperative biomechanics of vertebroplasty[J].Joint Bone Spine,2006,73:144-150.
[36]Lee WS ,Sung KH,Jeong HT,et al.Risk factors of developing new symptomatic vertebral compression fractures after percu-taneous vertebroplasty in osteoporotic patients[J].Eur Spine J,2006,15:1777-1783.
相似文献/References:
[1]何仕诚,滕皋军,方文,等.椎体成形术中同轴活检的应用[J].介入放射学杂志,2008,(11):796.
HE Shicheng,TENG Gaojun,FANG Wen,et al.Coaxial biopsy of vertebral body during percutaneous vertebroplasty[J].journal interventional radiology,2008,(12):796.
[2]何仕诚,滕皋军,邓钢,等.添加不同类型、比例的显影剂后骨水泥性能的变化[J].介入放射学杂志,2006,(04):238.
HE Shi-cheng,TENG Gao-jun,DENG Gang,et al.An in vitro evaluation of the property of acrylic bone cements mixed with different types and proportions of contrast agents[J].journal interventional radiology,2006,(12):238.
[3]王涛,吴春根,程永德,等.经皮椎体成形术治疗慢性症状性椎体压缩骨折的临床应用[J].介入放射学杂志,2009,(10):740.
WANG Tao,WU Chungen,CHENG Yongde,et al.Clinical application of percutaneous vertebroplasty in the treatment of chronic symptomatic osteoporotic vertebral compression fractures[J].journal interventional radiology,2009,(12):740.
[4]孙钢,金鹏,刘训伟,等.单球囊多次扩张椎体后凸成形术治疗多发性骨质疏松性脊柱压缩骨折[J].介入放射学杂志,2008,(02):106.
SUN Gang,JIN Peng,LIU Xunwei,et al.Kyphoplasty with single balloon multiple expansions for multi-level osteoporotic vertebral compressive fractures[J].journal interventional radiology,2008,(12):106.