Title:
Summary of the evidence concerning the correct use of radiation protective equipment in interventional medical staff
作者:
韦 清 柏晓玲 逄 锦 杨曾桢 梁青龙 成忠莎
Author(s):
WEI Qing BAI Xiaoling PANG Jin Yang Zengzhen LING Qinglong CHENG Zhongsha.
Department of Emergency Medicine, Guizhou Provincial People’s Hospital, Guiyang, Guizhou Province 550002, China
关键词:
【关键词】 介入诊疗 医务人员 X线辐射防护 证据总结
文献标志码:
A
摘要:
【摘要】 目的 筛选、评估和总结介入诊疗医务人员使用辐射防护用具的最佳证据。方法 计算机检索PubMed、Embase、Web of Science、The Cochrane Library、National Guideline Clearinghouse、中国医脉通指南网、中国知网、万方、维普、中国生物医学文献数据库等数据库中自建库至2020年12月关于介入诊疗医务人员如何正确使用辐射防护用具的系统评价、原始研究、专家共识及指南文献,同时追溯纳入文献的参考文献。由2名研究人员评价纳入文献的质量,并从纳入文献中提取证据。 结果 共纳入16篇文献,包括随机对照试验研究2篇,类试验研究9篇,队列研究1篇,观察性研究1篇,专家共识3篇。最终总结出10条最佳证据。结论 总结了介入诊疗医务人员使用辐射防护用具的证据,为避免介入诊疗医务人员盲目选择辐射防护用具、减少辐射暴露提供了依据。

参考文献/References:

[1] Parikh JR, Geise RA, Bluth EI, et al. Potential radiation- related effects on radiologists[J]. AJR Am J Roentgenol, 2017, 208: 595- 602.
[2] Della VE, Modenese A, Loney T, et al. Risk of cataract in health care workers exposed to ionizing radiation: a systematic review[J]. Med Lav, 2020, 111: 269- 284.
[3] Andreassi MG, Piccaluga E, Guagliumi G, et al. Occupational health risks in cardiac catheterization laboratory workers[J]. Circ Cardiovasc Interv, 2016, 9: e003273.
[4] Vincent LL, Dean LS. Shading operators from the Gray: are novel radiation barriers or changing physician behaviors the best next step?[J]. Catheter Cardiovasc Interv, 2020, 95: 148- 149.
[5] GBZ 130- 2013. 医用X射线诊断放射防护要求[S]. 北京:中国标准出版社, 2013.
[6] 中华人民共和国国家卫生健康委员会. 医用X射线诊断放射防护要求[EB/OL] http://www.nhc.gov.cn/wjw/pcrb/201410/445bab 815aac404c99a1ea71ac3553da.shtml, 2020- 12- 20.
[7] The Joanna Briggs Institute(JBI)[EB/OL]. https://jbi.global/critical- appraisal- tools, 2017- 11- 24.
[8] 米元元,沈 月,郝 彬,等. ICU患者肠内营养支持并发腹泻的循证护理实践[J]. 中华护理杂志, 2017, 52:1291- 1298.
[9] Uthoff H, Quesada R, Roberts JS, et al. Radioprotective lightweight caps in the interventional cardiology setting: a randomised controlled trial(PROTECT)[J]. EuroIntervention, 2015, 11: 53- 59.
[10] Alazzoni A, Gordon CL, Syed J, et al. Randomized controlled trial of radiation protection with a patient lead shield and a novel,nonlead surgical cap for operators performing coronary angiography or intervention[J]. Circ Cardiovasc Interv, 2015, 8: e002384.
[11] Wagner LK, Mulhern OR. Radiation- attenuating surgical gloves: effects of scatter and secondary electron production[J]. Radiology, 1996, 200: 45- 48.
[12] von Boetticher H, Lachmund J, Hoffmann W, et al. Optimizing staff radiation protection in radiology by minimizing the effective dose[J]. Rofo, 2006, 178: 287- 291.
[13] Mori H, Koshida K, Ishigamori O, et al. Evaluation of the effectiveness of X- ray protective aprons in experimental and practical fields[J]. Radiol Phys Technol, 2014, 7: 158- 166.
[14] Kayan M, Yasar S, Saygin M, et al. Investigation of X- ray permeability of surgical gloves coated with different contrast agents[J]. Anatol J Cardiol, 2016, 16: 424- 427.
[15] Hu P, Kong Y, Chen B, et al. Shielding effect of lead glasses on radiologists’ eye lens exposure in interventional procedures[J]. Radiat Prot Dosimetry, 2017, 174: 136- 140.
[16] Tavares JB, Sacadura- Leite E, Matoso T, et al. The importance of protection glasses during neuroangiographies: a study on radiation exposure at the lens of the primary operator[J]. Interv Neuroradiol, 2016, 22: 368- 371.
[17] Kamusella P, Scheer F, Ludtke CW, et al. Interventional angiography: radiation protection for the examiner by using lead- free gloves[J]. J Clin Diagn Res, 2017, 11: TC26-TC29.
[18] Honorio DE, Vanhavere F, Struelens L, et al. Effect of protective devices on the radiation dose received by the brains of interventional cardiologists[J]. EuroIntervention, 2018, 13: e1778- e1784.
[19] 王 遥,霍万里,熊 壮,等. TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J]. 中国医学物理学杂志, 2016, 33:553- 558.
[20] Waddell BS, Waddell WH, Godoy G, et al. Comparison of ocular radiation exposure utilizing three types of leaded glasses[J]. Spine(Phila Pa 1976), 2016, 41: E231- E236.
[21] Matsuda M, Suzuki T. Evaluation of Lead aprons and their maintenance and management at our hospital[J]. J Anesth, 2016, 30: 518- 521.
[22] Miller DL, Vano E, Bartal G, et al. Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology[J]. Cardiovasc Intervent Radiol, 2010, 33: 230- 239.
[23] Lopez PO, Dauer LT, Loose R, et al. ICRP publication 139: occupational radiological protection in interventional procedures[J]. Ann ICRP, 2018, 47: 1- 118.
[24] 胡 雁,郝玉芳. 循证护理学(第2版)[M]. 北京:人民卫生出版社, 2018:91- 93.
[25] 杨雪玲,于海鹏,邢文阁,等. 我国肿瘤介入专业技术人员职业暴露调查与分析[J]. 介入放射学杂志, 2019, 28:586- 590.
[26] Thomas RP, Grau M, Eldergash O, et al. Will X- ray safety glasses become mandatory for radiological vascular interventions?[J]. Cardiovasc Intervent Radiol, 2018, 41: 1074- 1080.
[27] Efstathopoulos EP, Pantos I, Andreou M, et al. Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures[J]. Br J Radiol, 2011, 84: 70- 77.

相似文献/References:

[1]廖磊,陆颜明,吴纪瑞,等.介入放射检查与治疗病人心理状态分析及护理[J].介入放射学杂志,1998,(03):176.
[2]韦清,柏晓玲,罗忠琛,等.贵阳市介入诊疗医务人员辐射防护用具使用现状及分析[J].介入放射学杂志,2020,29(04):393.
 WEI Qing,BAI Xiaoling,LUO Zhongchen,et al.Current situation and influencing factor analysis of radiation occupational protection of medical staff engaged in interventional diagnosis and treatment in Guiyang City of China[J].journal interventional radiology,2020,29(07):393.
[3]中国医师协会介入医师分会,中国研究型医院学会介入医学专委会.介入诊疗围手术期抗生素使用专家共识[J].介入放射学杂志,2022,31(04):319.
 Intervention Physician Branch of Chinese Medical Doctor Association NI Caifang,CHENG Yongde..Expert consensus on the use of antibiotics during perioperative period of interventional diagnosis and treatment[J].journal interventional radiology,2022,31(07):319.
[4]韦 清,柏晓玲,杨曾桢,等.介入诊疗医务人员正确维护辐射防护用具的最佳证据[J].介入放射学杂志,2023,32(05):491.
 WEI Qing,BAI Xiaoling,YANG Zengzhen,et al.Summary of the best evidences concerning the correct maintenance of radiation protective equipment by interventional medical staff [J].journal interventional radiology,2023,32(07):491.

备注/Memo

备注/Memo:
(收稿日期:2021- 03- 22)
(本文编辑:边 佶)
更新日期/Last Update: 2022-09-02