[1]邓佳欣,刘丽萍,赵 渝,等.可回收下腔静脉滤器研究文献计量学分析[J].介入放射学杂志,2022,31(04):339-345.
 DENG Jiaxin,LIU Liping,ZHAO Yu,et al.Bibliometrics analysis of the literature concerning the retrievable inferior vena cava filters[J].journal interventional radiology,2022,31(04):339-345.
点击复制

可回收下腔静脉滤器研究文献计量学分析()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
31
期数:
2022年04
页码:
339-345
栏目:
血管介入
出版日期:
2022-06-15

文章信息/Info

Title:
Bibliometrics analysis of the literature concerning the retrievable inferior vena cava filters
作者:
邓佳欣 刘丽萍 赵 渝 李凯平
Author(s):
DENG Jiaxin LIU Liping ZHAO Yu LI Kaiping.
Department of Vascular Surgery, First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
关键词:
【关键词】 下腔静脉 滤器 可回收 管理 文献计量学
文献标志码:
A
摘要:
【摘要】 目的 采用文献计量学方法分析可回收下腔静脉滤器(IVCF)的研究热点和前沿,为国内该领域研究提供参考。方法 基于科学网(Web of Science)TM核心数据库,采用CiteSpace软件对1975年至2020年可回收IVCF的总体特征和知识图谱进行定量统计和定性分析。结果 共检索到665篇有效文献,近20年发文量呈逐年上升趋势。美国发文量最多,为452篇,中国发文量排在第2位,为40篇。研究热点主要集中在远期并发症、随访管理、滤器回收、创伤患者滤器应用等方面。结论 当前可回收IVCF研究领域的成果主要集中在美国。未来研究可探讨高效的随访管理方式,以提高滤器回收率,减少滤器相关远期并发症。对于长期留置滤器患者抗凝治疗和滤器类型选择等相关问题,还需要大量高质量的临床试验和研究进一步探索。

参考文献/References:

[1] 中国医师协会介入医师分会, 中华医学会放射学分会介入专业委员会, 中国静脉介入联盟. 下腔静脉滤器置入术和取出术规范的专家共识(第2版)[J]. 中华医学杂志, 2020, 100:2092- 2101.
[2] 张福先. 腔静脉滤器的规范性应用与并发症的预防[J]. 中国普外基础与临床杂志, 2020, 27:396- 399.
[3] Saeed MJ, Turner TE, Brown DL. Trends in inferior vena cava filter placement by indication in the United States from 2005 to 2014[J]. JAMA Intern Med, 2017, 177: 1861- 1862.
[4] Marron RM, Rali P, Hountras P, et al. Inferior vena cava filters past, present, and future[J]. chest, 2020,158:2579- 2589.
[5] Sutphin PD, Reis SP, McKune A, et al. Improving inferior vena cava filter retrieval rates with the define, measure, analyze, improve, control methodology[J]. J Vasc Interv Radiol, 2015, 26: 491- 498.
[6] Klinken S, Humphries C, Ferguson J. Establishment of an inferior vena cava filter database and interventional radiology led follow- up - retrieval rates and patients lost to follow- up[J]. J Med Imaging Radiat Oncol, 2017, 61:630- 635.
[7] Angel LF, Tapson V, Galgon RE, et al. Systematic review of the use of retrievable inferior vena cava filters[J]. J Vasc Interv Radiol, 2011, 22:1522- 1530.
[8] 陈 悦, 陈超美, 刘则渊, 等. CiteSpace知识图谱的方法论功能[J]. 科学学研究, 2015, 33:242- 253.
[9] 邱均平, 杨思洛, 宋艳辉. 知识交流研究现状可视化分析[J]. 中国图书馆学报, 2012, 38:78- 89.
[10] 安兴茹. 我国词频分析法的方法论研究(Ⅰ)——统计分析要素的界定、分类及问题[J]. 情报杂志, 2016, 35:75- 80.
[11] 李凯平, 刘智平. 下腔静脉滤器置入远期并发症及随访管理的研究进展[J]. 护理研究, 2019, 33:4252- 4256.
[12] 贾中芝. 下腔静脉滤器断裂相关并发症及治疗策略[J]. 介入放射学杂志, 2021, 30:14- 17.
[13] Desai TR, Morcos OC, Lind BB, et al. Complications of indwelling retrievable versus permanent inferior vena cava filters[J]. J Vasc Surg Venous Lymphat Disord, 2014, 2:166- 173.
[14] 赵伯翔, 顾建平, 何 旭, 等. 下腔静脉滤器长期留置并发症CT随访的单中心研究[J]. 介入放射学杂志, 2016, 25:944- 948.
[15] Tsui B, An T, Moon E, et al. Retrospective review of 516 implantations of option inferior vena cava filters at a single health care system.[J]. J Vasc Interv Radiol, 2016, 27: 345- 353.
[16] Inferior vena cava(IVC) filters: initial communication: risk of adverse events with long term use[EB/OL]. http://www.fda.gov/Safety/MedWatch/SafetyInformation/SafetyAlertsforHumanMedical Products/ucm221707.htm, 2021- 3- 3.
[17] Andreoli JM, Lewandowski RJ, Vogelzang RL, et al. Comparison of complication rates associated with permanent and retrievable inferior vena cava filters: a review of the MAUDE database[J]. J Vasc Interv Radiol, 2014, 25: 1181- 1185.
[18] Haddadian B, Shaikh F, Djelmami- Hani M, et al. Sudden cardiac death caused by migration of a TrapEase inferior vena cava filter: case report and review of the literature[J]. Clin Cardiol, 2008, 31: 84- 87.
[19] Morales JP, Li X, Irony TZ, et al. Decision analysis of retrievable inferior vena cava filters in patients without pulmonary embolism[J]. J Vasc Surg Venous Lymphat Disord, 2013, 1:376- 384.
[20] Aurshina A, Brahmandam A, Zhang Y, et al. Patient perspectives on inferior vena cava filter retrieval[J]. J Vasc Surg Venous Lymphat Disord, 2019, 7:507- 513.
[21] Chen SL, Bosemani T, Krishnam MS, et al. Geometric changes of the inferior vena cava in trauma patients undergoing volume resuscitation: insight into dynamic stresses placed on inferior vena cava filters[J]. J Vasc Surg, 2012, 56: 583.
[22] Logan C, O’Connell N, Kavanagh J, et al. Out of sight, out of mind? An audit which proposes a follow- up and management pathway for inferior vena cava filters[J]. Thrombosis, 2016, 2016:6538456.
[23] Lynch FC. A method for following patients with retrievable inferior vena cava filters: results and lessons learned from the first 1,100 patients[J]. J Vasc Interv Radiol, 2011, 22:1507- 1512.
[24] Zhou D, Spain J, Moon E, et al. Retrospective review of 120 celect inferior vena cava filter retrievals: experience at a single institution[J]. J Vasc Interv Radiol, 2012, 23: 1557- 1563.
[25] Gyang E, Zayed M, Harris EJ, et al. Factors impacting follow- up care after placement of temporary inferior vena cava filters[J]. J Vasc Surg, 2013, 58: 440- 445.
[26] Charlson ME, Pompei P, Ales KL, et al. A new method of classifying prognostic comorbidity in longitudinal studies: deve-lopment and validation[J]. J Chronic Dis, 1987, 40: 373- 383.
[27] Winters JP, Morris CS, Holmes CE, et al. A multidisciplinary quality improvement program increases the inferior vena cava filter retrieval rate[J]. Vasc Med, 2017, 22: 51- 56.
[28] Litwin RJ, Huang SY, Sabir SH, et al. Impact of an inferior vena cava filter retrieval algorithm on filter retrieval rates in a cancer population[J]. J Vasc Surg Venous Lymphat Disord, 2017, 5: 689- 697.
[29] Mohapatra A, Liang NL, Chaer RA, et al. Persistently low inferior vena cava filter retrieval rates in a population- based cohort[J]. J Vasc Surg Venous Lymphat Disord, 2019, 7:38- 44.
[30] Kaufman JA, Barnes GD, Chaer RA, et al. Society of interventional radiology clinical practice guideline for inferior vena cava filters in the treatment of patients with venous thromboembolic disease: developed in collaboration with the American College of Cardiology, American College of Chest Physicians, American College of Surgeons Committee on Trauma, American Heart Association, Society for Vascular Surgery, and Society for Vascular Medicine[J]. J Vasc Interv Radiol,2020,31:1529- 1544.
[31] Li J, Zhu Y, Chen W, et al. Incidence and locations of deep venous thrombosis of the lower extremity following surgeries of tibial plateau fractures: a prospective cohort study[J]. J Orthop Surg Res, 2020, 15:605.
[32] Dalla VM, Grolla E, Bonanni L, et al. Are too many inferior vena cava filters used? Controversial evidences in different clinical settings: a narrative review[J]. Intern Emerg Med, 2018, 13:145- 154.
[33] Rogers FB, Cipolle MD, Velmahos G, et al. Practice management guidelines for the prevention of venous thromboembolism in trauma patients: the EAST practice management guidelines work group.[J]. J Trauma, 2002, 53: 142- 164.
[34] Haut ER, Garcia LJ, Shihab HM, et al. The effectiveness of prophylactic inferior vena cava filters in trauma patients: a systematic review and meta- analysis[J]. JAMA Surg, 2014, 149: 194- 202.
[35] Sarosiek S, Rybin D, Weinberg J, et al. Association between inferior vena cava filter insertion in trauma patients and in- hospital and overall mortality[J]. JAMA Surg, 2017, 152: 75- 81.
[36] Hemmila MR, Osborne NH, Henke PK,et al. Prophylactic inferior vena cava filter placement does not result in a survival benefit for trauma patients[J]. Ann Surg, 2015, 262:577-585.
[37] Janne d’Othee B, Faintuch S, Reedy AW, et al. Retrievable versus permanent caval filter procedures: when are they cost- effective for interventional radiology?[J]. J Vasc Interv Radiol, 2008, 19: 384- 392.
[38] Eifler AC, Lewandowski RJ, Gupta R, et al. Optional or permanent: clinical factors that optimize inferior vena cava filter utilization[J]. J Vasc Interv Radiol, 2013, 24: 35- 40.
[39] Ghatan CE, Ryu RK. Permanent versus retrievable inferior vena cava filters: rethinking the“one- filter- for- all” approach to mechanical thromboembolic prophylaxis[J]. Semin Intervent Ra-diol, 2016, 33: 75- 78.
[40] Dake MD, Murphy TP, Kramer AH, et al. Final two- year outcomes for the sentry bioconvertible inferior vena cava filter in patients requiring temporary protection from pulmonary embolism[J]. J Vasc Interv Radiol , 2020, 31: 221- 230.
[41] Tritschler T, Kraaijpoel N, Le Gal G, et al. Venous thrombo- embolism: advances in diagnosis and treatment[J]. JAMA, 2018, 320:1583- 1594.
[42] Kearon C, Akl EA, Ornelas J, et al. Antithrombotic therapy for VTE disease:CHEST guideline and expert panel report[J]. Chest, 2016, 149: 315- 352.
[43] Mahmood SS, Abtahian F, Fogerty AE, et al. Anticoagulation is associated with decreased inferior vena cava filter- related complications in patients with metastatic carcinoma[J]. Am J Med, 2017, 130: 77- 82.
[44] Mismetti P, Decousus H, Moulin N. Initial treatment of venous thromboembolic events[J]. Rev Prat, 2007, 57:751- 757.
[45] Weinberg I, Jaff MR. Can inferior vena cava filters change their struts?[J]. JACC Cardiovasc Interv, 2016, 9:2449- 2451.

相似文献/References:

[1]黄连军,蒋世良,赵世华,等.经皮穿刺下腔静脉滤器置入术[J].介入放射学杂志,2000,(02):76.
[2]中华医学会放射学分会介入学组.下腔静脉滤器置入术和取出术规范的专家共识[J].介入放射学杂志,2011,(05):340.
 Radiology Branch of Chinese Medical Association..The consensus among Chinese interventional experts on the standard of inferior vena cava filter insertion and retrieval Academic Group of Interventional Radiology[J].journal interventional radiology,2011,(04):340.
[3]肖 亮,童家杰,解世洋,等.滤器置入后症状性下腔静脉血栓形成的介入治疗[J].介入放射学杂志,2011,(05):380.
 XIAO Liang,TONG Jia-jie,XIE Shi-yang,et al.The interventional therapy of symptomatic inferior vena cava thrombosis developed after filter implantation[J].journal interventional radiology,2011,(04):380.
[4]邵国良,李焕祥,韩苏阳,等. 上腔静脉可回收滤器的置入六例[J].介入放射学杂志,2011,(12):993.
 SHAO Guo-liang,LI Huan-xiang,HAN Su-yang,et al. The implantation of retrievable superior vena cava filter report of 6 cases[J].journal interventional radiology,2011,(04):993.
[5]刘秋松,梅雀林,李彦豪.下腔静脉畸形并发症及其介入诊疗[J].介入放射学杂志,2015,(07):621.
 LIU Qiu-song,MEI Que-lin,LI Yan-hao.The complications due to inferior vena cava abnormality and their interventional management[J].journal interventional radiology,2015,(04):621.
[6]张 强,李晓光,游国超,等.下腔静脉漂浮血栓介入治疗临床效果[J].介入放射学杂志,2018,27(09):883.
 ZHANG Qiang,LI Xiaoguang,YOU Guochao,et al.Interventional treatment for floating thrombi in inferior vena cava: observation of clinical effect[J].journal interventional radiology,2018,27(04):883.
[7]张富钊,李 静,郑国学,等.急性滤器相关下腔静脉血栓形成危险因素分析[J].介入放射学杂志,2022,31(01):27.
 ZHANG Fuzhao,LI Jing,ZHENG Guoxue,et al.Analysis of the risk factors for acute filter-related inferior vena cava thrombosis[J].journal interventional radiology,2022,31(04):27.
[8]王晓东,萧炜亮,刘 琼,等.旋转DSA导引改良导丝成襻法在回收钩贴壁下腔静脉滤器取出术中的应用[J].介入放射学杂志,2022,31(07):707.
 WANG Xiaodong,XIAO Weiliang,LIU Qiong,et al.Application of rotational DSA-guided modified loop snare technique in the retrieval of adhered inferior vena cava filter[J].journal interventional radiology,2022,31(04):707.
[9]夏永辉,徐 克,管宇珩,等.置管溶栓术治疗下腔静脉滤器内栓子的疗效观察[J].介入放射学杂志,2013,(01):27.
 XIA Yong? hui,XU Ke,GUAN Yu? heng,et al. Catheter?蛳 directed thrombolysis for embolus trapped by the inferior vena cava filter[J].journal interventional radiology,2013,(04):27.
[10]赵伯翔,顾建平,何 旭,等.下腔静脉滤器长期留置并发症CT随访的单中心研究[J].介入放射学杂志,2016,(11):944.
 ZHAO Bo- xiang,GU Jian- ping,HE Xu,et al.Follow- up checkups with CT scan for the complications induced by long- term retention of indwelling IVC filters: a single- center study[J].journal interventional radiology,2016,(04):944.
[11]李绍钦,贾中芝,喻贤珍,等.滤器致下腔静脉穿孔1例 [J].介入放射学杂志,2017,(05):411.
 LI Shaoqin,JIA Zhongzhi,YU Xianzhen,et al.Perforation of inferior vena cava caused by inferior vena cava filter: report of one case with literature review[J].journal interventional radiology,2017,(04):411.
[12]施万印,陈 亮,刘长建,等.血管内介入治疗滤器源性下腔-髂静脉长段阻塞8例 [J].介入放射学杂志,2017,(11):978.
 SHI Wanyin,CHEN Liang,LIU Changjian,et al.Endovascular treatment for filter- related long segment obstruction of IVC and iliac vein: preliminary results in 8 patients[J].journal interventional radiology,2017,(04):978.
[13]贾中芝,顾建平.下腔静脉滤器图像识别[J].介入放射学杂志,2018,27(02):101.
 JIA Zhongzhi,GU Jianping.The identification of inferior vena cava filters by images[J].journal interventional radiology,2018,27(04):101.
[14]徐燕能,袁 罡,胡 伟,等.机械性抽栓治疗滤器源性症状性下腔静脉-髂静脉血栓形成8例[J].介入放射学杂志,2019,28(12):1136.
 XU Yanneng,YUAN Gang,HU Wei,et al.Mechanical thrombectomy for the treatment of filter- induced symptomatic IVC- iliac vein thrombosis: preliminary results in 8 patients[J].journal interventional radiology,2019,28(04):1136.
[15]王天成,肖煜东,张子曙.滤器置入后下腔静脉闭塞,穿孔1例[J].介入放射学杂志,2020,29(06):552.
 WANG Tiancheng,XIAO Yudong,ZHANG Zishu..Occlusion and perforation of inferior vena cava caused by implantation of inferior vena cava filter: report of one case with literature review[J].journal interventional radiology,2020,29(04):552.
[16]贾中芝.下腔静脉滤器断裂相关并发症及治疗策略[J].介入放射学杂志,2021,30(01):14.
 JIA Zhongzhi..The inferior vena cava filter fracture-related complications and their treatment strategies[J].journal interventional radiology,2021,30(04):14.
[17]余海洋,游德淑,杨代斌,等.下腔静脉基于圆周长的直径与投照横径临床对比研究[J].介入放射学杂志,2022,31(12):1165.
 YU Haiyang,YOU Deshu,YANG Daibin,et al.The inferior vena cava diameter obtained from the calculation of its circumference and its transverse diameter obtained from the projection measurement: a clinical comparison study[J].journal interventional radiology,2022,31(04):1165.
[18]顾晓诚,秦立昊,朴则宇,等.Aegisy和OptEase滤器未取出危险因素分析及其风险预测[J].介入放射学杂志,2023,32(11):1065.
 GU Xiaocheng,QIN Lihao,PIAO Zeyu,et al.Risk factor analysis of unremoved Aegisy and OptEase filters and its nomogram risk prediction model[J].journal interventional radiology,2023,32(04):1065.

备注/Memo

备注/Memo:
(收稿日期:2021- 03- 16)
(本文编辑:边 佶)
更新日期/Last Update: 2022-05-11