[1]罗 刚,泮思林,孙宏晓,等.二代Amplatzer动脉导管未闭封堵器在儿童膜周部室间隔缺损治疗中的应用[J].介入放射学杂志,2021,30(11):1105-1108.
 LUO Gang,PAN Silin,SUN Hongxiao,et al.Application of Amplatzer duct occluder Ⅱ in treating sick children with perimembranous ventricular septal defect: clinical efficacy and preliminary experience[J].journal interventional radiology,2021,30(11):1105-1108.
点击复制

二代Amplatzer动脉导管未闭封堵器在儿童膜周部室间隔缺损治疗中的应用()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
30
期数:
2021年11
页码:
1105-1108
栏目:
心脏介入
出版日期:
2021-11-25

文章信息/Info

Title:
Application of Amplatzer duct occluder Ⅱ in treating sick children with perimembranous ventricular septal defect: clinical efficacy and preliminary experience
作者:
罗 刚 泮思林 孙宏晓 王葵亮 纪志娴 杜占慧
Author(s):
LUO Gang PAN Silin SUN Hongxiao WANG Kuiliang JI Zhixian DU Zhanhui.
Heart Disease Center, Affiliated Women and Children’s Hospital of Qingdao University, Qingdao, Shandong Province 266034, China
关键词:
【关键词】 Amplatzer动脉导管未闭封堵器 室间隔缺损残余漏 介入治疗 儿童
文献标志码:
A
摘要:
【摘要】 目的 总结二代Amplatzer动脉导管未闭封堵器(ADO Ⅱ)介入治疗膜周部室间隔缺损(pmVSD)的效果和经验。 方法 回顾性研究2016年1月至2020年10月青岛大学附属妇女儿童医院采用ADOⅡ介入封堵治疗的15例pmVSD(9例伴发膜部瘤)、1例法洛氏四联症VSD修补术后残余漏、1例pmVSD修补术后残余漏患儿。术后随访观察是否存在残余分流、瓣膜反流和心律失常等并发症。结果 17例患儿中男10例,女7例;中位年龄3.25岁(1.7~8.0岁),中位体质量16.0 kg(10.5~31.0 kg);中位室间隔缺损为3.0 mm(2.0~5.0 mm),中位肺血管阻力为1.4 Wood U/m2(1.1~2.2 Wood U/m2),中位肺循环/体循环血流量比值(Qp/Qs)为1.29(1.0~1.7)。11例患儿接受顺行路径释放ADO Ⅱ,6例为逆行路径,术中均无封堵器脱落、死亡等严重并发症。所有患儿定期随访,随访时间为16.6个月(1~40个月),无完全性房室传导阻滞及主动脉瓣反流。 结论 pmVSD与残余漏解剖结构多变,选择ADOⅡ介入封堵治疗在减少并发症、保证治疗效果上具有优势,尤其适用于pmVSD伴膜部瘤患儿。完全性房室传导阻滞仍然是术后需持续关注的严重并发症。

参考文献/References:

[1] Suligoj B, Cernic N, Zorc M, et al. Retrograde transcatheter closure of ventricular septal defect with Amplatzer Duct Occluder Ⅱ[J]. Postepy Kardiol Interwencyjnej, 2016, 12: 177-178.
[2] Saurav A, Kaushik M, Mahesh Alla V, et al. Comparison of percutaneous device closure versus surgical closure of peri-membranous ventricular septal defects: a systematic review and meta-analysis[J]. Catheter Cardiovasc Interv, 2015, 86: 1048-1056.
[3] Polat TB, Turkmen E. Transcatheter closure of ventricular septal defects using the Amplatzer Duct Occluder Ⅱdevice: a single-center experience[J]. Postepy Kardiol Interwencyjnej, 2016, 12: 340-347.
[4] Koneti NR, Sreeram N, Penumatsa RR, et al. Transcatheter retrograde closure of perimembranous ventricular septal defects in children with the Amplatzer duct occluder Ⅱ device[J]. J Am Coll Cardiol, 2012, 60:2421-2422.
[5] Zhao LJ, Han B, Zhang JJ, et al. Transcatheter closure of congenital perimembranous ventricular septal defect using the Amplatzer duct occluder 2[J]. Cardiol Young, 2018, 28: 447-453.
[6] 赵鹏军,余志庆,傅立军,等. 新型动脉导管未闭封堵器封堵膜周部室间隔缺损的临床应用[J]. 介入放射学杂志, 2011, 20:433-435.
[7] 中国医师协会心血管内科分会先心病工作委员会. 常见先天性心脏病介入治疗中国专家共识. 二、室间隔缺损介入治疗[J]. 介入放射学杂志, 2011, 20:87-92.
[8] Ghaderian M, Merajie M, Mortezaeian H, et al. Efficacy and safety of using Amplatzer Ductal Occluder for transcatheter closure of perimembranous ventricular septal defect in pediatrics[J]. Iran J Pediatr, 2015, 25: e386.
[9] Forsey J, Kenny D, Morgan G, et al. Early clinical experience with the new Amplatzer Ductal Occluder Ⅱ for closure of the persistent arterial duct[J]. Catheter Cardiovasc Interv, 2009, 74:615-623.
[10] Ji W, Zhang ZF, Zhao WC, et al. Clinical study of transcatheter occlusion in treating ventricular septal defect combined with right coronary cusp bulge[J]. J Intervent Med, 2018, 1: 205-211.
[11] Atik S, Saltik L. Transcatheter closure of ventricular septal defect with two different devices[J]. Cardiol Young, 2018, 28: 1364-1366.
[12] Roos-Hesselink JW, Meijboom FJ, Spitaels SE, et al. Outcome of patients after surgical closure of ventricular septal defect at young age: longitudinal follow-up of 22-34 years[J]. Eur Heart J, 2004, 25: 1057-1062.
[13] 赵 璐,刘 芳,吴 琳,等. 先天性心脏病术后残余室间隔缺损介入治疗及中长期随访[J]. 中国循证儿科杂志, 2014, 9:371-376.
[14] Santhanam H, Yang L, Chen Z, et al. A meta-analysis of transcatheter device closure of perimembranous ventricular septal defect[J]. Int J Cardiol, 2018, 254: 75-83.

相似文献/References:

[1]王舒,郭德文.轴位成角心血管造影术的方法及其临床应用[J].介入放射学杂志,1994,(01):55.
[2]周 勇,黄新苗,赵先仙,等. 涤纶膜外套式镍钛合金室间隔缺损封堵器的物理性能测试[J].介入放射学杂志,2012,(10):839.
 ZHOU Yong,HUANG Xin- miao,ZHAO Xian-xian,et al. Physical property of polyester coated nitinol ventricular septal defect occluder[J].journal interventional radiology,2012,(11):839.
[3]高力明,许旭东,汤佳旎,等.纳米膜单铆型室间隔缺损封堵器动物实验研究[J].介入放射学杂志,2015,(06):509.
 GAO Li- ming,Xu Xu- dong TANG Jia- ni,TAN Hong- wei,et al.Nano material occluder of single rivet type used for percutaneous closure of ventricular septal defect: an experimental study in dogs[J].journal interventional radiology,2015,(11):509.
[4]张坡,朱鲜阳,张端珍,等.先天性心脏病介入封堵术后血小板减少及影响因素[J].介入放射学杂志,2016,(06):483.
 ZHANG Po,ZHU Xian-yang,ZHANG Duan-zhen,et al.Thrombocytopenia occurring after percutaneous transcatheter closure of congenital heart defects and its related factors [J].journal interventional radiology,2016,(11):483.

备注/Memo

备注/Memo:
(收稿日期:2020-11-18)
(本文编辑:边 佶)
更新日期/Last Update: 2021-11-22