[1]刘伟宾,黄连军,郭久芳,等.心血管疾病患者在介入诊疗过程中辐射剂量分析[J].介入放射学杂志,2014,(11):941-944.
 LIU Wei bin,HUANG Lian jun,GUO Jiu fang,et al.The distribution of radiation dose in patients with cardiac diseases during interventional procedure[J].journal interventional radiology,2014,(11):941-944.
点击复制

心血管疾病患者在介入诊疗过程中辐射剂量分析 ()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2014年11期
页码:
941-944
栏目:
心脏介入
出版日期:
2014-11-25

文章信息/Info

Title:
The distribution of radiation dose in patients with cardiac diseases during interventional procedure
作者:
刘伟宾 黄连军 郭久芳 肖 颖 徐卫星 任献玲 邱 威 赵培源 杨博鑫 李 军 王 金
Author(s):
LIU Wei bin HUANG Lian jun GUO Jiu fang XIAO Ying XU Wei xing REN Xian ling QIU Wei ZHAO Pei yuan YANG Bo xin LI Jun WANG Jin.
Department of Interventional Therapy, Affiliated Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
关键词:
【关键词】 心血管疾病 介入诊疗 辐射剂量 辐射防护
文献标志码:
A
摘要:
【摘要】 目的 分析心血管疾病患者在介入诊疗过程中的辐射剂量,探讨其预防措施。方法 抽取用SIEMENS Aritis Zee Floor DSA 介入诊疗的心血管疾病患者186例,记录随机配备的辐射检测系统显示的总辐射时间(T)、剂量面积乘积(DAP)、累积剂量(CD),由DAP估算有效剂量(ED),由CD估算最高皮肤剂量值(PSD)。结果 患者所受T为0.9 ~ 71.2 min,平均10.5 min,> 30 min的9例(4.8%); ED为0.11 ~ 282.9 mSv,平均32.2 mSv,> 100 mSv的10例(5.4%);1 Gy < PSD(1/2CD) ≤ 3 Gy的40例(21.5%),PSD(1/2CD) > 3 Gy的4例(2.2%);1 Gy < PSD(4/5CD) ≤ 3 Gy的53例(28.5%),PSD(4/5CD) > 3 Gy的14例(7.5%)。T与PSD(1/2 CD)、PSD(4/5CD)、ED在置信度(双侧)为0.01时显著相关。结论23.7% ~ 36.0%心血管介入患者可因累积剂量导致严重的皮肤损伤,5.4%心血管介入患者有显著的致癌危险。

参考文献/References:

[1] Fletcher DW, Miller DL, Balter S, et al. Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures[J]. J Vasc Interv Radiol, 2002, 13: 391 397.
[2] UNSCEAR. 2008REPORT VOLUME1[R]. 2008: 53.
[3] Miller DL, Balter S, Cole PE, et al. Radiation doses in interventional radiology procedures: the RAD IR study: part I: overall measures of dose[J]. J Vasc Interv Radiol, 2003, 14: 711 727.
[4] Miller DL, Balter S, Cole PE, et al. Radiation doses in interventional radiology procedures: The RAD IR study Part II: Skin dose[J]. J Vasc Interv Radiol, 2003, 14: 977 990.
[5] 刘 彬, 白 玫. 不同版本国际放射防护委员会建议组织器官权重因子对心脏介入诊疗所致有效剂量的影响[J]. 介入放射学杂志, 2009, 18: 923 926.
[6] ICRP. Avoidance of radiation injuries from medical interventional procedures [M]. ICRP Publication 85.Oxford: pergamon Press, 2000.
[7] ICRP. The 2007 Recommendation of the International Commission on Radiological Protection[M]. ICRP Publication 103.Oxford: Pergamon press, 2008.
[8] 王智廷, 曹国全, 闻彩云, 等. 冠状动脉介入治疗中操作者所受剂量的综合研究[J]. 介入放射学杂志, 2013, 22: 834 837.
[9] Mooney RB, Mckinstry J. Paediatric dose reduction with the introduction of digital fluorography[J]. Radiat Prot Dosimetry, 2001, 94: 117 120.
[10] Nikolic B, Spies JB, Campbell L, et al. Uterine artery embolization: Reduced radiation with refined technique[J]. J Vasc Interv Radiol, 2001, 12: 39 44.
[11] Xu T, Le HQ, Molloi S. Patient specific region of interest fluoroscopy device for X ray dose reduction[J]. Radiology, 2003, 226: 585 592.
[12] Suzuki S, Furui S, Yamakawa T, et al. Radiation exposure to patients’ skin during cardiac resynchronization therapy[J]. Europace, 2009, 11: 1683 1688.
[13] Chida K, Kagaya Y, Saito H, et al. Evaluation of patient radiation dose during cardiac interventional procedures: what is the most effective method?[J]. Acta Radiol, 2009, 50: 474 481.
[14] Miller DL, Balter S, Noonan PT, et al. Minimizing radiation induced skin injury in interventional radiology procedures[J]. Radiology, 2002, 225: 329 336.

相似文献/References:

[1]梁君.右肾母细胞瘤术前介入诊疗一例[J].介入放射学杂志,2000,(04):205.
[2]曹喜才,贺能树,孙建中,等.介入诊断与治疗十年工作体会[J].介入放射学杂志,1998,(03):160.
[3].首届全国骨与关节系统及四肢血管介入技术学术交流大会征文通知[J].介入放射学杂志,2000,(01):31.
[4]刘玉清.迎接挑战,为推进新世纪介入放射学的发展而奋进[J].介入放射学杂志,2000,(01):1.
[5]程景林,万 俊,王爱玲.介入诊疗对心血管病患者外周淋巴细胞DNA的损伤[J].介入放射学杂志,2012,(07):551.
 CHENG Jing? lin,WAN Jun,WANG Ai- ling.. Acute chromosomal DNA damage of human lymphocytes caused by radiation exposure produced in performing interventional cardiovascular procedures[J].journal interventional radiology,2012,(11):551.
[6]刘伟宾,黄连军,郭久芳,等.冠心病介入诊疗中透视与电影辐射剂量率对比分析[J].介入放射学杂志,2015,(06):524.
 LIU Wei-bin,HUANG Lian-jun,GUO Jiu-fang,et al.Radiation dose rate received by patients with coronary heart disease during interventional management: comparison between fluoroscopy and movies[J].journal interventional radiology,2015,(11):524.
[7]阳秀春,莫 伟,向 华,等.标准化沟通模式在介入科病房的应用[J].介入放射学杂志,2019,28(03):296.
 YANG Xiuchun,MO Wei,XIANG Hua,et al.Application of standardized communication mode in interventional ward[J].journal interventional radiology,2019,28(11):296.
[8]刘伟宾,马晓海,吴文辉,等.先心病患者在介入诊疗中辐射剂量控制分析[J].介入放射学杂志,2021,30(08):837.
 LIU Weibin,MA Xiaohai,WU Wenhui,et al.Analysis of radiation dose control in patients with congenital heart disease during interventional procedure[J].journal interventional radiology,2021,30(11):837.
[9]09年肝癌中西医临床协作专家委员会.原发性肝癌中西医结合介入诊疗专家共识 (试行第一版)[J].介入放射学杂志,2021,30(11):1079.
 09 Expert Committee on Clinical Coordination of Traditional Chinese and Western Medicine for Liver Cancer ZHENG Jiasheng,YANG Guowang.Interventional expert consensus on integrated traditional Chinese and Western medicine for the diagnosis and treatment of hepatocellular carcinoma(trial editionⅠ)[J].journal interventional radiology,2021,30(11):1079.

备注/Memo

备注/Memo:
(收稿日期:2014-01-15)
(本文编辑:侯虹鲁)
更新日期/Last Update: 2014-11-24