参考文献/References:
[1] Ferguson DD. Evaluation and management of benign esophageal strictures[J]. Dis Esophagus, 2005, 18: 359- 364.
[2] Choi EK, Song HY, Kim JW, et al. Covered metallic stent placement in the management of cervical esophageal strictures[J]. J Vasc Interv Radiol, 2007, 18: 888- 895.
[3] Cheng YS, Li MH, Chen WX, et al. Temporary partially- covered metal stent insertion in benign esophageal stricture[J]. World J Gastroenterol, 2003, 9: 2359- 2361.
[4] Schembre D, Dever JB, Glenn M, et al. Esophageal reconstitution by simultaneous antegrade/retrograde endoscopy: re- establishing patency of the completely obstructed esophagus[J]. Endoscopy, 2011, 43: 434- 437.
[5] Bick BL, Song LM, Buttar NS, et al. Stent- associated esophagores- piratory fistulas: incidence and risk factors[J]. Gastrointest Endosc, 2013, 77: 181- 189.
[6] Stewart DJ, Balamurugan R, Everitt NJ, et al. Ten- year experience of esophageal self- expanding metal stent insertion at a single institution[J]. Dis Esophagus, 2013, 26: 276- 281.
[7] Zhao JG, Li YD, Cheng YS, et al. Long- term safety and outcome of a temporary self- eapanding metallic stent for achalasia: a prospective study with a 13- years single- center experience[J]. Eur Radiol, 2009, 19: 1973- 1980.
[8] Li YD, Tang GY, Cheng YS, et al. 13- years follow- up of a peospective comparison of the long- term clinical efficacy of temporary self- expanding metallic stents and pneumatic dilatation for the treatment of achalasia in 120 patients[J]. AJR Am J Roentgenol, 2010, 195: 1429- 1437.
[9] Hirdes MM, Siersema PD, Vleggaar FP. A new fully covered metal stent for the treatment of benign and malignant dysphagia: a prospective follow- up study[J]. Gastrointest Endosc, 2012, 75: 712- 718.
[10] Vlavianos P, Zabron A. Clinical outcomes, quality of life, advantages and disadvantages of metal stent placement in the upper gastrointestinal tract[J]. Curr Opin Support Palliat Care, 2012, 6: 27- 32.
[11] Ham YH, Kim GH. Plastic and biodegradable stents for complex and refractory benign esophageal strictures[J]. Clin Endosc, 2014, 4: 295- 300.
[12] Yim HB. Self- expanding metallic stents and self- expanding plastic stents in the palliation of malignant oesophageal dysphagia[J]. Ann Palliat Med, 2014, 3: 41- 46.
[13] Kornowski R, Hong MK, Tio FO, et al. In- stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia[J]. J Am Coll Cardiol, 1998, 31: 224- 230.
[14] Ferguson DD. Evaluation and management of benign esophageal strictures[J]. Dis Esophagus, 2005, 18: 359- 364.
[15] Na HK, Song HY, Kim JH, et al. How to design the optimal self- expandable oesophageal metallic stents: 22 years of experience in 645 patients with malignant strictures[J]. Eur Radiol, 2013, 23: 786- 796.
[16] Zhu YQ, Cui WG, Cheng YS, et al. Biodegradable rapamycin- eluting nano- fiber membrane- covered metal stent placement to reduce fibroblast proliferation in experimental stricture in a canine model[J]. Endoscopy, 2013, 45: 458- 468.
[17] Zhu YQ, Cui WG, Cheng YS, et al. Evaluation of biodegradable paclitaxel- eluting nanofibre- covered metal stents for the treatment of benign cardia stricture in an experimental model[J]. Br J Surg, 2013, 100: 784- 793.
[18] Zhu YQ, Cheng YS, Li F, et al. Application of the newly developed stents in the treatment of benign cardia stricture: an experimental comparative study[J]. Gastrointest Endosc, 2011, 73: 329- 337.
[19] 曹亚玲, 黄茂涛, 冯早明. 生物可降解食管支架的研究进展[J]. 中国介入影像与治疗学, 2014, 10: 688- 691.
[20] 黄茂涛, 曹亚玲, 周绍兵, 等. 聚乳酸己内酯共聚物食管支架的动物实验初探[J]. 四川大学学报?医学版, 2015, 46: 305- 306.
[21] 颜 波, 狄镇海. 生物可降解食管支架的研究进展[J]. 广东医学, 2014, 35: 3759- 3762.
[22] 高小龙, 冷德嵘, 刘春俊, 等. 新型可降解食管支架的设计研究[J]. 中国医疗器械信息, 2016, 22: 1- 7.
[23] 颜 波, 施瑞华, 冯亚东, 等. 新型可降解食管支架动物实验研究[J]. 介入放射学杂志, 2016, 25: 155- 159.
[24] Gu XE, Zheng YF, Cheng Y, et al. In vitro corrosion and biocompatibility of binary magnesium alloys[J]. Biomaterials, 2009, 30: 484- 498.
[25] Li X, Chu CL, Liu L, et al. Biodegradable poly- lactic acid based- composite reinforced unidirectionally with high- strength magnesium alloy wires[J]. Biomaterials, 2015, 49: 135- 144.
[26] 杨 凯, 朱悦琦, 程英升. 食管良性狭窄药物镁合金可降解支架研究现状及展望[J]. 介入放射学杂志, 2015, 24: 452- 456.
[27] 皇甫强, 袁思波, 于振涛, 等. 可降解镁合金管材及其胆管内支架[J]. 广州化工, 2015, 43: 54- 56.
[28] 张红梅, 张利鹏. 可降解血管支架材料的表面性能及生物相容性[J]. 中国组织工程研究, 2016, 20: 6445- 6450.
[29] 赵 辉, 雷 民. 可降解AZ31镁合金支架在兔腹主动脉内的降解时间和降解效果[J]. 中国组织工程研究, 2016, 20: 1165- 1170.
[30] 王 武, 程英升, 李永东, 等. 可降解镁合金覆膜支架治疗兔颈总动脉侧壁型动脉瘤可行性研究[J]. 介入放射学杂志, 2016, 25: 151- 154.
[31] Wong HM, Yeung KW, Lam KO, et al. A biodegradable polymer- based coating to control the performance of magnesium alloy orthopaedic implants[J]. Biomaterials, 2010, 31: 2084- 2096.
[32] Haude M, Erbel R, Erne P, et al. Safety and performance of the drug- eluting absorbable metal scaffold(DREAMS) in patients with de- novo coronary lesions: 12 month results of the prospective, multicentre, first- in- man BIOSOLVE- I trial[J]. Lancet, 2013, 381: 836- 844.
[33] Tanaka T, Takahashi M, Nitta N, et al. Newly developed biodegradable stents for benign gastrointestinal tract stenoses: a preliminary clinical trial[J]. Digestion, 2006, 74: 199- 205.
[34] Davies RR, Davies JA. Rabbit gastrointestinal physiology[J]. Vet Clin North Am Exot Anim Pract, 2003, 6: 139- 153.
相似文献/References:
[1]陈 华,赵仙先.生物可降解镁合金支架研究现状[J].介入放射学杂志,2011,(01):62.
CHEN Hua,ZHAO Xian-xian.Biodegradable magnesium-alloy stent: current situation in research[J].journal interventional radiology,2011,(09):62.
[2]杨 凯,朱悦琦,程英升.食管良性狭窄药物镁合金可降解支架研究现状及展望[J].介入放射学杂志,2015,(05):452.
YANG Kai,ZHU Yue qi,CHENG Ying sheng.The application of drug eluting biodegradable magnesium alloy stent in treating esophageal benign stricture: current research status and prospect[J].journal interventional radiology,2015,(09):452.
[3]郭 俊,沈下贤,张必利,等.可降解支架现状及研究进展 [J].介入放射学杂志,2016,(02):178.
GUO Jun,SHEN Xia- xian,ZHANG Bi- li,et al.Biodegradable stents: current status and research progress[J].journal interventional radiology,2016,(09):178.