[1]何广荣,李洪伟.心房内心电图定位技术在新生儿超声引导下颈内静脉置入中心静脉导管2例[J].介入放射学杂志,2016,(05):461-462.
 HE Guang- rong,LI Hong- wei.Ultrasound- guided implantation of PICC via internal jugular vein in neonates by using intra- atrial ECG positioning technique: report of two cases[J].journal interventional radiology,2016,(05):461-462.
点击复制

心房内心电图定位技术在新生儿超声引导下颈内静脉置入中心静脉导管2例 ()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2016年05期
页码:
461-462
栏目:
病例报道
出版日期:
2016-05-25

文章信息/Info

Title:
Ultrasound- guided implantation of PICC via internal jugular vein in neonates by using intra- atrial ECG positioning technique: report of two cases
作者:
何广荣 李洪伟
Author(s):
HE Guang- rong LI Hong- wei
Department of Neonates, Second Hospital of Tianjin Medical University, Dongying, Tianjin 300211, China
关键词:
【关键词】 心房内心电图定位 新生儿 颈内静脉 PICC
文献标志码:
A

参考文献/References:

[1] Sellitto M, Messina F. Central venous catheterization and throm- bosis in newborns: update on diagnosis and management[J]. J Matern Fetal Neonatal Med, 2012, 25: 26- 28.
[2] 王爱忠, 谢 红, 江 伟. 超声引导下的区域阻滞和深静脉穿刺置管[M]. 上海: 上海科学技术出版社, 2011: 108- 109.
[3] Kayashima K, Yoshino H, Ueki M, et al. On the possibility of the central venous catheterization through the pediatric axillary veins using ultrasound guidance[J]. Masui, 2012, 61: 998- 1002.
[4] 张龙新, 林传涛, 陈小琳. 超声引导技术在新生儿颈内静脉穿刺置管中的应用[J]. 中华医学超声杂志?电子版, 2012, 9: 491- 494.
[5] 韩传钢, 江 云, 王力甚, 等. 超声定位在婴幼儿颈内静脉置管术中的应用[J]. 长江大学学报, 2012, 9: 12- 13.
[6] 崔功浩, 魏欣甫, 陶建华, 等. 颈内静脉穿刺置管的解剖学基础及临床应用[J]. 中国临床解剖学杂志, 1994, 12: 36- 38.
[7] 贺 生, 刘荣志, 范 真, 等. 新生儿颈内静脉穿刺置管术的应用解剖[J]. 中国临床解剖学杂志, 2001, 19: 235- 236.
[8] Schummer W, Schummer C, Schelenz C, et al. Central venous catheters: the inability of ‘intra- atrial ECG’ to prove adequate positioning[J]. Br J Anaesth, 2004, 93: 193- 198.
[9] Kremser J, Kleemann F, Reinhart K, et al. Optimized method for correct left- sided central venous catheter placement under electro- cardiographic guidance[J]. Br J Anaesth, 2011, 107: 567- 572.
[10] 郭 玲, 秦 英, 王国蓉, 等. 成人中心静脉置管腔内心电图稳定性及影响因素研究[J]. 中华护理杂志, 2015, 50: 724- 727.
[11] Moureau NL, Dennis GL, Ames E, et al. Electrocardiogram(EKG)guided peripherally inserted central catheter placement and tip position: results of a trial to replace radiological cofirmation[J]. J Assoc Vasc Access, 2010, 15: 8- 14.
[12] Pittiruti M, Bertollo D, Briglia E, et al. The intracavitary ECG method for positioning the tip of central venous catheters: results of an Italian multicenter study[J]. J Vasc Access, 2012, 13: 357- 365.
[13] 周莲清, 谌永毅, 王佳丽, 等. 心房内心电图引导PICC尖端定位方法的临床应用研究[J]. 护士进修杂志, 2013, 28: 2021- 2023.
[14] 毛燕君, 董惠娟, 张玲娟, 等. DSA引导下调整中心静脉置管头端异位的尝试[J]. 介入放射学杂志, 2009, 18: 624- 626.
[15] Nadroo AM, Glass RB, Lin J, et al. Changes in upper extremity position cause migration of peripherally inserted central catheters in neonates[J]. Pediatrics, 2002, 110: 131- 136.
[16] Nowlen TT, Rosenthal GL, Johnson GL, et al. Pericardial effusion and tamponade in infants with central catheters[J]. Pediatrics, 2002, 110: 137- 142.
[17] Fricke BL, Racadio JM, Duckworth T, et al. Placement of peripherally inserted central catheters without fluoroscopy in children: initial catheter tip position[J]. Radiology, 2005, 234: 887- 892.
[18] Racadio JM, Doellman DA, Johnson ND, et al. Pediatric peripherally inserted central catheters: complication rates related to catheter tip location[J]. Pediatrics, 2001, 107: E28.
[19] 陈玉瑛, 纪 平, 唐 玲, 等. 极低体重儿PICC导管定位的临床处理[J]. 护士进修杂志, 2008, 23: 2004- 2005.
[20] Rossetti F, Pittiruti M, Lamperti M, et al. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study[J]. J Vasc Access, 2015, 16: 137- 143.
[21] 张红革, 张文华, 吴晓静, 等. 盐水电极心房内心电图辅助PICC导管定位技术的应用[J]. 护士进修杂志, 2013, 28: 835- 836.
[22] Anestis N, Christos FC, Ioannis P, et al. Thoracic duct injury due to left subclavicular vein catheterization: A new conservative approach to a chyle fistula using biological glue[J]. Int J Surg Case Rep, 2012, 3: 330- 332.

相似文献/References:

[1]杨培金,郭新会,刘士超,等. 经动脉栓塞治疗新生儿肺隔离症16例[J].介入放射学杂志,2013,(12):1042.
 YANG Pei? jin,GUO Xin? hui,LIU Shi? chao,et al. Transarterial embolization for the treatment of pulmonary sequestration in newborn infants: initial experience in 16 cases[J].journal interventional radiology,2013,(05):1042.
[2]罗 刚,刘 娜,王葵亮,等.双导丝技术在新生儿危重肺动脉瓣狭窄治疗中的应用[J].介入放射学杂志,2019,28(08):726.
 LUO Gang,LIU Na,WANG Kuiliang,et al.The application of buddy-wire technique in the treatment of neonatal critical pulmonary stenosis[J].journal interventional radiology,2019,28(05):726.
[3]王思宝,泮思林,罗 刚,等.危重肺动脉瓣狭窄介入治疗临床研究 [J].介入放射学杂志,2021,30(09):870.
 WANG Sibao,PAN Silin,LUO Gang,et al.Interventional therapy for critical pulmonary stenosis: a clinical study [J].journal interventional radiology,2021,30(05):870.

备注/Memo

备注/Memo:
(收稿日期:2015-05-05)
(本文编辑:俞瑞纲)
更新日期/Last Update: 2016-05-16