[1]吴 宁,蒲 红,王 娜,等.慢性完全闭塞冠状动脉患者介入术前双源CT评估及指导分析[J].介入放射学杂志,2014,(12):1069-1072.
 WU Ning,PU Hong,WANG Na,et al.Application of preoperative dual source CT angiography in evaluating chronic total occlusive coronary artery disease and in guiding interventional management[J].journal interventional radiology,2014,(12):1069-1072.
点击复制

慢性完全闭塞冠状动脉患者介入术前双源CT评估及指导分析 ()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2014年12期
页码:
1069-1072
栏目:
临床研究
出版日期:
2014-12-25

文章信息/Info

Title:
Application of preoperative dual source CT angiography in evaluating chronic total occlusive coronary artery disease and in guiding interventional management
作者:
吴 宁 蒲 红 王 娜 李 刚 陶客言 赵 原
Author(s):
WU Ning PU Hong WANG Na LI Gang TAO Ke yan ZHAO Yuan.
Sichuan Provincial People’s Hospital, Chengdu, Sichuan Province 610072, China
关键词:
【关键词】 双源CT 慢性完全闭塞冠状动脉病变 介入术 血管评估
文献标志码:
A
摘要:
【摘要】 目的 分析双源CT对慢性完全闭塞冠状动脉病变的介入术前血管评估及术中指导价值。方法 选取300例慢性完全闭塞冠状动脉患者为研究对象,分别进行双源CT血管造影以及冠状动脉造影检查,并评价不同检查方法对介入治疗的患者的实践效果。结果 300例冠状动脉病变患者中共涉及340处慢性完全闭塞病变,行双源CT血管重建可获得病变具体长度,钙化识别率上可达76.5%,显著高于冠脉造影(41.2%),220例涉及240处完全闭塞病变先后接受介入治疗,有120处(50%)获得成功。结论 双源CT在钙化病变鉴别方面表现出了良好的应用效果,能够以冠脉血管为目标对象,进行三维图像的构建,从而科学指导介入治疗的开展。

参考文献/References:

[1] 林晓强, 朱 海, 詹源胜. 成功开通慢性完全闭塞冠状动脉病变血管能提高患者的生存率[J]. 心脏杂志, 2013, 06: 685 688.
[2] 郑 望, 魏易洪, 邓 兵, 等. 经桡动脉冠脉介入治疗中桡动脉痉挛发生的相关因素[J]. 介入放射学杂志, 2013, 22: 986 988.
[3] 陈进业, 刘发俊, 沈桂东. 慢性完全闭塞冠状动脉病变介入治疗的并发症及其处理措施[J]. 齐齐哈尔医学院学报, 2012, 33: 2619 2620.
[4] Rajani R, Shmilovich H, Nakazato R, et al. Relationship of epicardial fat volume to coronary plaque, severe coronary stenosis, and high risk coronary plaque features assessed by coronary CT angiography[J]. J Cardiovasc Comput Tomogr, 2013, 7: 125 132.
[5] 王 芳. 逆向介入治疗慢性完全闭塞冠状动脉病变的术中护理[J]. 护理学杂志, 2013, 28: 59 60.
[6] 宋泽军, 马向东, 黄卫芳, 等. CT血管成像对冠状动脉慢性闭塞病变介入治疗的应用价值[J]. 武警医学, 2014, 25: 42 43, 47.
[7] Ko SM, Kim NR, Kim DH, et al. Assessment of image quality and radiation dose in prospective ECG triggered coronary CT angiography compared with retrospective ECG gated coronary CT angiography[J]. Int J Cardiovasc Imaging, 2010, 26: 93 101.
[8] Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual source CT coronary angiography: First experience in a high pre test probability population without heart rate control[J]. Eur Radiol, 2006, 16: 2739 2747.

相似文献/References:

[1]徐 锋,卜元园,邹宝明,等.双源CT与冠状动脉造影评估冠状动脉狭窄对照研究[J].介入放射学杂志,2015,(12):1044.
 XU Feng,BO Yuan- yuan,ZOU Bao- ming,et al.Dual source CT coronary angiography and selective coronary angiography for evaluation of coronary artery stenosis: a control study Section I,[J].journal interventional radiology,2015,(12):1044.

备注/Memo

备注/Memo:
(收稿日期:2014-08-03)
(本文编辑:李 欣)
更新日期/Last Update: 2014-12-24