[1]何忆雯,秦永文,丁仲如.64排螺旋CT冠脉成像在冠心病诊断中的应用[J].介入放射学杂志,2007,(01):10.
HE Yi-wen,QIN Yong-wen,DING Zhong-ru.Preliminary evaluation of64-slice spiral CT coronary angiograpy in patients with coronary artery disease[J].journal interventional radiology,2007,(01):10.
点击复制
64
排螺旋
CT
冠脉成像在冠心病诊断中的应用()
《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]
- 卷:
-
- 期数:
-
2007年01期
- 页码:
-
10
- 栏目:
-
心脏介入
- 出版日期:
-
2007-01-15
文章信息/Info
- Title:
-
Preliminary evaluation of64-slice spiral CT coronary angiograpy in patients with coronary artery disease
- 作者:
-
何忆雯; 秦永文; 丁仲如
-
200433上海第二军医大学长海医院心内科
- Author(s):
-
HE Yi-wen; QIN Yong-wen; DING Zhong-ru
-
Department of Cardiology,Changhai Hospital,Second Military Medical University,Shanghai200433,China
-
- 关键词:
-
64排螺旋CT; 冠状血管造影术; 冠心病
- 分类号:
-
R448.3;R543.3
- 文献标志码:
-
A
- 摘要:
-
目的评价64排螺旋CT冠状动脉(冠脉)成像(CTA)在冠心病诊断中的应用价值。方法以选择性冠脉造影(SCA)结果为金标准,采用64排螺旋CT对68例疑诊冠心病患者的冠脉主干及主要分支272节段进行重建和分析,评价其诊断冠心病的灵敏度和特异度。结果CTA能够清晰显示冠脉主干及其分支狭窄、钙化、开口起源异常及桥血管病变,CTA发现钙化病变52节段,SCA仅发现钙化病变35节段。CTA诊断冠脉病变的灵敏度96.33%,特异度98.16%,阳性预测值97.22%,阴性预测值97.56%。其中对左主干、左前降支病变及>75%的病变灵敏度最高,分别达到100%和94.4%。结论CTA对冠脉狭窄病变、桥血管、开口畸形、支架管腔均显影良好,对冠心病诊断有较高的准确性,对钙化病变诊断率优于冠脉造影,可以作为冠心病高危人群无创性筛选检查及冠脉支架术后随访手段。
参考文献/References:
[1]Raff GL,Gallagher MJ,O'Neill WW,et al.Diagnostic accuracy of noninvasive coronary angiography using64-slice spiral computed tomography[J].J Am Coll Cardiol,2005,46:552-557.
[2]Wang YN,Jin ZY,Kong LY,et al.Comparison of coronary angiography between64-slice and16-slice spiral CT[J].Zhongguo Yi Xue Ke Xue Yuan Xue Bao,2006,28:26-31.
[3]Plass A,Grunenfelder J,Leschka S,et al.Coronary artery imaging with64-slice computed tomography from cardiac surgical perspective[J].Eur J Cardiothorac Surg,2006,30:109-116.
[4]Haberl R,Tittus J,Bohme E,et al.Multislice spiral computed tomographic angiography of coronary arteries in patients with suspected coronary artery disease:an effective filter before catheter angiography[J]芽Am Heart J,2005,149:1112-1129.
[5]Brodoefel H,Reimann A,Heuschmid M,et al.Non-invasive coronary angiography with16-slice spiral computed tomography:image quality in patients with high heart rates[J].Eur Radiol,2006,16:1434-1441.
[6]Shim SS,Kim Y,Lim SM.Improvement of image quality with beta-blocker premedication on ECG-gated16-MDCT coronary angiography[J].AJR,2005,184:649-654.
[7]Leta R,Carreras F,Alomar X,et al.Non-invasive coronary angiography with16multidetector-row spiral computed tomography:a comparative study with invasive coronary angiography[J].Rev Esp Cardiol,2004,57:217-224.
备注/Memo
- 备注/Memo:
-
收稿日期:2006-07-10
更新日期/Last Update:
2007-01-15