[1]广东省肿瘤介入重点实验室,广东省放射介入质控中心,广东省护理学会介入护理专委会.电离辐射铅防护用具的应用与管理专家共识[J].介入放射学杂志,2024,33(09):939-943.
 Guangdong Provincial Key Laboratory of Tumor Interventional Diagnosis and Treatment.Expert consensus on the application and management of ionizing radiation lead protective equipment[J].journal interventional radiology,2024,33(09):939-943.
点击复制

电离辐射铅防护用具的应用与管理专家共识()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
33
期数:
2024年09
页码:
939-943
栏目:
指南与共识
出版日期:
2024-09-17

文章信息/Info

Title:
Expert consensus on the application and management of ionizing radiation lead protective equipment
作者:
广东省肿瘤介入重点实验室广东省放射介入质控中心广东省护理学会介入护理专委会
Author(s):
Guangdong Provincial Key Laboratory of Tumor Interventional Diagnosis and Treatment
Guangdong Provincial Interventional Radiology Quality Control Center;Interventional Nursing Committee of Guangdong Provincial Nursing Association
关键词:
【关键词】电离辐射铅防护用具清洁维护报废标准
文献标志码:
A
摘要:
【摘要】为了帮助各医疗机构科学规范使用及管理铅防护用具,促进医务人员的职业安全与健康,特制定《电离辐射铅防护用具的应用与管理专家共识》(以下简称共识)。通过系统文献检索,综合国内多领域专家两轮函询的意见后制定了本共识。该共识在用具的选择、配置、清洁与维护及检验等4个方面进行专业指导,旨在为广大从事介入放射学的医务工作者提供临床借鉴。

参考文献/References:

[1]中华人民共和国国家质量监督检验检疫总局.电离辐射防护与辐射源安全基本标准:GB 18871-2002[S].北京:中国标准出版社,2004.
[2]Mourtada F,Clement CH,Dauer LT,et al. Occupational radiological protection in brachytherapy[J]. Ann ICRP,2021,50:5-75.
[3]Kellens PJ,De Hauwere A,Gossye T,et al. Integrity of personal radiation protective equipment(PRPE):a 4-year longitudinal follow-up study[J]. Insights Imaging,2022,13:183.
[4]中华人民共和国国家卫生健康委员会.放射诊断放射防护要求:BZ 130-2020[S]. 北京:中国标准出版社,2020.
[5]王春青,胡雁.JBI证据预分级及证据推荐级别系统(2014版)[J].护士进修杂志,2015,30:964-967.
[6]Rees CR,Duncan BWC. Get the Lead off our backs![J]. Tech Vasc Interv Radiol,2018,21:7-15.
[7]Engstrom A,Isaksson M,Larsson PA,et al. Lead aprons and thyroid collars:to be,or not to be?[J]. J Radiol Prot,2023,43:3.
[8]Lee WJ,Bang YJ,Cha ES,et al. Lifetime cancer risks from occupational radiation exposure among workers at interventional radiology departments[J]. Int Arch Occup Environ Health,2021,94:139-145.
[9]Franken Y,Huyskens CJ. Guidance on the use of protective lead aprons in medical radiology protection efficiency and correction factors for personal dosimetry[R].The Netherlands:Centre for Radiation Protection,Eindhoven University of Technology,2022.
[10]Lopez PO,Dauer LT,Loose R,et al. ICRP publication 139:occupational radiological protection in interventional procedures[J]. Ann ICRP,2018,47:1-118.
[11]朱静.常熟市2004-2012年度医学放射工作人员职业健康体检指标分析及防护应对[D].苏州:苏州大学,2014.
[12]Shafiee M,Rashidfar R,Abdolmohammadi J,et al. A study to assess the knowledge and practice of medical professionals on radiation protection in interventional radiology[J]. Indian J Radiol Imaging,2020,30:64-69.
[13]Kidon J,Polaczek-Grelik K,Zurek P,et al. Exposure of the eye lens and brain for interventional cardiology staff[J]. Postepy Kardiol Interwencyjnej,2021,17:298-304.
[14]Cousins C,Miller DL,Bernardi G,et al. ICRP PUBLICATION 120:Radiological protection in cardiology[J].Ann ICRP,2013,42:1-125.
[15]刘伟,何星.PET-CT诊断项目工作人员受照剂量及相关场所辐射水平测量与分析[J].中国辐射卫生,2019,28:278-281.
[16]庞宁东,王嵘,杨敏玲,等.某医院介入放射工作人员职业受照剂量调查[J].中国职业医学,2017,44:242-244.
[17]Komemushi A,Takashima S,Nagai A,et al. Practical radiation protection for interventional radiologist[J]. Interv Radiol(Higashimatsuyama),2022,7:54-57.
[18]ICRP,Khong PL,Ringertz H,et al. ICRP publication 121:radiological protection in paediatric diagnostic and interventional radiology[J]. Ann ICRP,2013,42:1-63.
[19]Cornacchia S,Errico R,La Tegola L,et al. The new lens dose limit:implication for occupational radiation protection[J]. Radiol Med,2019,124:728-735.
[20]Marshall NW,Faulkner K,Clarke P. An investigation into the effect of protective devices on the dose to radiosensitive organs in the head and neck[J]. Br J Radiol,1992,65:799-802.
[21]Fetterly K,Schueler B,Grams M,et al. Head and neck radiation dose and radiation safety for interventional physicians[J]. JACC Cardiovasc Interv,2017,10:520-528.
[22]Balter S,Rodriguez MA,Pike JA,et al. Microbial contamination risk and disinfection of radiation protective garments[J]. Health Phys,2021,120:123-130.
[23]Gilat R,Mitchnik I,Beit Ner E,et al. Bacterial contamination of protective Lead garments in an operating room setting[J]. J Infect Prev,2020,21:234-240.
[24]韦清,柏晓玲,杨曾桢,等.介入诊疗医务人员正确维护辐射防护用具的最佳证据[J].介入放射学杂志,2023,32:491-494.
[25]Matsuda M,Suzuki T. Evaluation of Lead aprons and their maintenance and management at our hospital[J]. J Anesth,2016,30:518-521.
[26]褚永华,朱锋杰,王志鸿,等.医用辐射防护产品检测系统[J].中国生物医学工程学报,2020,39:375-379.
[27]Lambert K,McKeon T. Inspection of lead aprons:criteria for rejection[J]. Health Phys,2001,80:S67-S69.

备注/Memo

备注/Memo:
(收稿日期:2024-02-08)
(本文编辑:新宇)
更新日期/Last Update: 2024-09-15