[1]洪凤鸣,俞炎平,徐 敏,等.3D打印非共面模板引导125I粒子植入治疗肝恶性肿瘤剂量学研究[J].介入放射学杂志,2023,32(08):760-764.
 HONG Fengming,YU Yanping,XU Min,et al.The dosimetric study of three-dimensional printing non-coplanar template-guided 125I seed implantation for hepatic malignancy[J].journal interventional radiology,2023,32(08):760-764.
点击复制

3D打印非共面模板引导125I粒子植入治疗肝恶性肿瘤剂量学研究()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
32
期数:
2023年08
页码:
760-764
栏目:
非血管介入
出版日期:
2023-08-29

文章信息/Info

Title:
The dosimetric study of three-dimensional printing non-coplanar template-guided 125I seed implantation for hepatic malignancy
作者:
洪凤鸣 俞炎平 徐 敏 罗 君 郭立文 宋丹军 曾 晖 郝伟远 曹 非 郑家平
Author(s):
HONG Fengming YU Yanping XU Min LUO Jun GUO Liwen SONG Danjun ZENG Hui HAO Weiyuan CAO Fei ZHENG Jiaping.
Department of Interventional Therapy, Affiliated Cancer Hospital of University of Chinese Academy of Sciences (Zhejiang Provincial Cancer Hospital), Hangzhou, Zhejiang Province 310022, China
关键词:
【关键词】 125I放射性粒子 3D打印非共面模板 肝恶性肿瘤 剂量
文献标志码:
A
摘要:
【摘要】 目的 比较3D打印非共面模板(3D- PNCT)引导125I粒子植入治疗肝恶性肿瘤术前与术后剂量学结果,探索3D- PNCT辅助放射性粒子植入治疗肝恶性肿瘤的可行性。方法 回顾性收集2019年6月至2021年12月在浙江省肿瘤医院介入科接受3D- PNCT引导125I粒子植入术治疗的肝癌患者20例,处方剂量130~150 Gy。搜集并对比术前、术后剂量学参数,包括D90、D100、V90、V100、V150、V200、CTV体积。按照英国哥伦比亚癌症中心粒子植入质量评价标准对操作评价。结果 20例患者设计打印20块模板,技术成功19例,实际针数术后与术前一致8例,术中优化增加针道8例,减少3例。术后验证质量评价结果显示为优的患者10例,良5例,中3例,差2例,技术失败1例。与术前计划相比,术后D90、D100、V200、CTV平均体积差异无统计学差异(P>0.05)。V90、V100、V150差异有统计学差异(P<0.05)。结论 使用3D- PNCT引导125I粒子植入治疗肝恶性肿瘤主要剂量学指标在手术前、后基本吻合,有良好的治疗精确性,能满足临床需求。

参考文献/References:

[1] 杨腾蛟. 3D打印模板辅助125I粒子植入治疗肝脏恶性肿瘤的临床研究[D]. 河北:承德医学院, 2021.
[2] Wang JJ, Yuan HS, Li JN, et al. CT- guided radioactive seed implantation for recurrent rectal carcinoma after multiple therapy[J]. Med Oncol, 2010, 27: 421- 429.
[3] 张国正,郑家平,邵国良,等. 肝细胞肝癌125I粒子植入影响肿瘤局部控制临床研究[J]. 介入放射学杂志, 2019, 28:656- 660.
[4] 中华医学会放射肿瘤治疗学分会,中国医师学会放射治疗专业委员会,中国研究型医院放射治疗专业委员会,等. 3D打印共面模板辅助CT引导放射性125I粒子植入治疗专家共识[J].中华医学杂志, 2018, 98:2815- 2818.
[5] Zhou G, Liu W, Zhang Y, et al. Application of three- dimensional printing in interventional medicine[J]. J Interv Med, 2020, 3: 1- 16.
[6] Ji Z, Sun H, Jiang Y, et al. Comparative study for CT- guided 125I seed implantation assisted by 3D printing coplanar and non- coplanar template in peripheral lung cancer[J]. J Contemp Brac-hytherapy, 2019, 11: 169- 173.
[7] Keyes M, Morris WJ, Spadinger I, et al. Radiation oncology and medical physicists quality assurance in British Columbia Cancer Agency Provincial Prostate Brachytherapy Program[J]. Brachy- therapy, 2013, 12: 343- 355.
[8] Hongtao Z, Xuemin D, Huimin Y, et al. Dosimetry study of three- dimensional print template- guided precision 125I seed implantation[J]. J Cancer Res Ther, 2016, 12: C159- C165.
[9] Westendorp H, Surmann K, Van De Pol SMG, et al. Dosimetric impact of contouring and image registration variability on dynamic 125I prostate brachytherapy[J]. Brachytherapy, 2017, 16: 572- 578.
[10] 霍 彬,侯朝华,叶剑飞,等. CT引导下术中实时计划对胸部肿瘤125I粒子植入治疗的价值[J]. 中华放射肿瘤学杂志, 2013, 22:400- 403.
[11] 吉 喆,姜玉良,郭福新,等. 3D打印个体化非共面模板辅助放射性粒子植入治疗恶性肿瘤的剂量学验证[J]. 中华放射医学与防护杂志, 2016, 36:662- 666.
[12] 姜玉良,王 皓,吉 喆,等. CT引导辅助3D打印个体化非共面模板指导125I粒子治疗盆腔复发肿瘤剂量学研究题录[J]. 中华放射肿瘤学杂志, 2016, 25:959- 964.
[13] 霍 斌,王 磊,王海涛,等. 模板联合肋骨钻孔技术辅助放射性粒子植入治疗肺癌的可行性[J]. 山东大学学报(医学版), 2017, 55:26- 31.
[14] 何庄超,何玉成,朱柏霖,等. 非共面3D打印导板在CT引导下肺癌125I粒子植入术中的穿刺误差分析[J]. 影像诊断与介入放射学, 2019, 28:335- 339.
[15] 朱柏霖,何玉成,何庄超,等. 3D打印非共面导板复位对125I粒子植入术中穿刺准确性的影响[J].中国介入影像与治疗学,2020, 17:153- 156.

相似文献/References:

[1]蒋 妮,蒋 蕾,邱 燕,等.125I放射性粒子食管支架置入治疗食管癌伴吞咽困难患者的护理[J].介入放射学杂志,2014,(12):1106.
 JIANG Ni,JIANG Lei,QIU Yan,et al.Nursing care for esophageal carcinoma patients treated with 125I seed esophageal stent implantation[J].journal interventional radiology,2014,(08):1106.
[2]费 伦,郭金友,郑家平,等.CT引导下放射性粒子125I植入治疗骨转移瘤患者的临床研究[J].介入放射学杂志,2020,29(09):930.
 FEI Lun,GUO Jinyou,ZHENG Jiaping,et al.CT-guided 125I particles implantation for the treatment of patients with bone metastases: a clinical study[J].journal interventional radiology,2020,29(08):930.

备注/Memo

备注/Memo:
(收稿日期:2022- 08- 10)
(本文编辑:茹 实)
更新日期/Last Update: 2023-08-29