[1]王丽英,薛 嵋,陶 雍,等.1 047例静脉输液港导管功能的分析与处理[J].介入放射学杂志,2021,30(02):191-195.
WANG Liying,XUE Mei,TAO Yong,et al.Analysis and management of catheter dysfunction of central venous port access system in 1 047 patients[J].journal interventional radiology,2021,30(02):191-195.
点击复制
1 047例静脉输液港导管功能的分析与处理()
《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]
- 卷:
-
30
- 期数:
-
2021年02
- 页码:
-
191-195
- 栏目:
-
护理论坛
- 出版日期:
-
2021-02-25
文章信息/Info
- Title:
-
Analysis and management of catheter dysfunction of central venous port access system in 1 047 patients
- 作者:
-
王丽英; 薛 嵋; 陶 雍; 姜高松; 武林燕; 祝 敏
-
- Author(s):
-
WANG Liying; XUE Mei; TAO Yong; JIANG Gaosong; WU Liyan; ZHU Min.
-
Department of Nursing, Affiliated Tumor Hospital of Fudan University; Department of Oncology, Shanghai Medical College of Fudan University, Shanghai 200032, China
-
- 关键词:
-
【关键词】 植入式输液港; 导管功能评估; 导管功能障碍; CINAS评估表; 处理
- 文献标志码:
-
A
- 摘要:
-
【摘要】 目的 引进并应用CINAS(catheter injection and aspiration)评估表,调查植入式静脉输液港(CVPAS)导管功能的现状,并描述导管功能障碍的处理与结局。方法 完成CINAS的翻译和评分者信度检测后,采用横断面研究方法,在复旦大学附属肿瘤医院血管通路护理门诊,调查2017年12月1至31日接受插针的患者的CVPAS导管功能,并记录患者的一般资料,导管功能障碍的处理与结局。结果 CINAS评分者信度高,并调查了1 047例患者的CVPAS导管功能,其中908例(86.7%)导管功能完好,导管功能障碍的发生率为13.3%(139/1 047),主要表现为推注通畅而回抽困难(7.4%,10例)或无法回抽(4.9%); 93.5%(130/139)的导管功能障碍处理成功,其中92.3%通过推注适量0.9%NaCl溶液,或患者配合活动(包括深咳嗽,变换体位,活动肢体等)得以解除,其余7.8%则通过调整无损伤针位置。结论 CINAS评估表能高效完整地评估导管功能,便于临床应用与推广,CVPAS导管功能障碍主要表现为推注通畅而回抽困难或无法回抽,推注0.9%NaCl溶液、患者适当活动及调整无损伤针位置是导管功能障碍的主要处理措施,护理人员可基于评估结果进行个性化综合处理。