[1]周春高,施海彬,刘圣,等.自制可回收下腔静脉滤器预防急性肺栓塞的实验研究[J].介入放射学杂志,2007,(06):394.
 ZHOU Chun-gao,SHI Hai-bin,LIU Sheng,et al.Experimental evaluatioin of a new retrievable inferior vena cava filter for protection from acute pulmonary embolism in canine[J].journal interventional radiology,2007,(06):394.
点击复制

自制可回收下腔静脉滤器预防急性肺栓塞的实验研究()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2007年06期
页码:
394
栏目:
实验研究
出版日期:
2007-06-15

文章信息/Info

Title:
Experimental evaluatioin of a new retrievable inferior vena cava filter for protection from acute pulmonary embolism in canine
作者:
周春高施海彬刘圣
210029南京医科大学第一附属医院介入放射科
Author(s):
ZHOU Chun-gaoSHI Hai-binLIU ShengWANG Cheng-huLIU Hai-riLI Lin-sun.
Department of Radiology,the First Affiliated Hospital of Nanjing Medical University,Nanjing210029,China
关键词:
静脉血栓腔静脉滤器肺栓塞动物实验
分类号:
R543.1
文献标志码:
B
摘要:
目的探讨一种新型可回收下腔静脉滤器预防急性肺栓塞的有效性、安全性。方法12只犬制备成髂股深静脉血栓模型,分为滤器组(实验组)与无滤器组(对照组),每组6只。滤器组在深静脉血栓脱落前于对侧股静脉置入下腔静脉滤器,其后使血栓脱落;对照组直接使血栓脱落即形成肺动脉栓塞。通过血栓脱落前后的肺动脉造影、肺动脉测压以及动脉血氧饱和度测定评价滤器的血栓捕获性能。结果滤器组均成功捕获脱落的深静脉血栓,无一例发生肺动脉栓塞,8h后滤器均能成功回收;而对照组在推注血栓后均发生了肺动脉栓塞。结论自制可回收下腔静脉滤器能有效预防下肢深静脉急性血栓脱落引起的肺动脉栓塞,其置入和回收简便。

参考文献/References:

[1]张鹏,施海彬,刘圣,等.犬下肢深静脉血栓模型的实验研究[J].介入放射学杂志,2006,15:299-302.
[2]Kinney TB.Update on inferior vena cava filters[J].J Vasc Inter Radiol,2003,14:425-440.
[3]Tagami H,Utoh J,Sun LB熏et al.Effects of recombinant tissue-type plasminogen activator on life-threatening acute pulmonary thromboembolism in a canine model:a comparative study of e6010and alteplase[J].Ann Thorac Cardiovasc Surg,2000,6:299-303·
[4]方纬,季顺东,刘秀杰,肺动脉血栓放射免疫显像实验研究[J].中华核医学杂志,2002,22:188-190.
[5]李家增,贺石林,王鸿利,等主编.血栓病学[M].北京出版社,1998.5-8.
[6]Millward SF,Oliva VL,Bell SD,et al.Gunther Tulip retrieva-ble vena cava filter:results from the registry of the Canadian interventional radiology association[J].J Vasc Interv Radiol,2001,12:1053-1058.
[7]Asch MR.Initial experience in humans with a new retrievable in-ferior vena cava filter[J].Radiology,2002,225:835-844.
[8]Streiff MB.Vena cava filters:a comprehensive review(Review)[J].Blood,2000,95:3669-3677.

相似文献/References:

[1]秦定文,施海彬,刘圣,等.自制下腔静脉支架式滤器安全性的动物实验研究[J].介入放射学杂志,2008,(05):349.
 QIN Dingwen,SHI Haibin,LIU Sheng,et al.Animal experimental study of safety for a self-made vena cava stent-filter[J].journal interventional radiology,2008,(06):349.
[2]姚立正,戴真煜,李文会,等.腔静脉滤器在深静脉血栓治疗中的应用价值及置入体会[J].介入放射学杂志,2007,(11):737.
 YAO Li-zheng,DAI Zhen-yu,LI Wen-hui,et al.Value and deploying experience of IVC-filter in treating DVT[J].journal interventional radiology,2007,(06):737.

备注/Memo

备注/Memo:
收稿日期:2006-12-01
更新日期/Last Update: 2007-06-15