[1]汤铭杰,张磊,王勇,等.锥形束CT成像技术在肝恶性肿瘤血管介入治疗中的应用及其研究进展 [J].介入放射学杂志,2024,33(12):1360-1366.
 TANG Mingjie,ZHANG Lei,WANG Yong,et al.Cone-beam CT technique:its application in endovascular interventional treatment of hepatic malignancy and its research progress[J].journal interventional radiology,2024,33(12):1360-1366.
点击复制

锥形束CT成像技术在肝恶性肿瘤血管介入治疗中的应用及其研究进展
(/HTML)

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
33
期数:
2024年12
页码:
1360-1366
栏目:
综述
出版日期:
2024-12-25

文章信息/Info

Title:
Cone-beam CT technique:its application in endovascular interventional treatment of hepatic malignancy and its research progress
作者:
汤铭杰张磊王勇朱海东
Author(s):
TANG MingjieZHANG LeiWANG YongZHU Haidong.
Medical College of Southeast University,Nanjing,Jiangsu Province 210009,China
关键词:
【关键词】肝恶性肿瘤锥形束CT介入放射学
文献标志码:
A
摘要:
【摘要】血管介入治疗是局部治疗肝恶性肿瘤的常见方法,对于术中图像的获取、识别和处理等有较高要求。锥形束CT(cone-beam computed tomography,CBCT)成像是一种容积成像模式,可提供病灶及肿瘤供血动脉的额外信息,目前已逐渐用于肝恶性肿瘤介入术中并仍在不断更新和发展,被国内外多项共识、指南推荐。近年来,单期CBCT成像技术已发展成熟并广泛应用于临床,多项新的CBCT成像技术提高了CBCT成像质量、拓展了CBCT成像技术应用范围。该文介绍了单期CBCT成像技术及其临床优势、部分新开发的CBCT成像技术进展,总结了目前CBCT成像技术在肝恶性肿瘤血管介入中的综合应用及应用中暴露的不足和局限性。

参考文献/References:

[1]Zheng RS,Zhang SW,Zeng HM,et al.Cancer incidence and mortality in China,2016[J].J Natl Cancer Cent 2022,2:1-9.
[2]Forner A,Reig M,Bruix J.Hepatocellular carcinoma[J].Lancet,2018,391:1301-1314.
[3]Zhu HD,Li HL,Huang MS,et al.Transarterial chemoembolization with PD-(L)1 inhibitors plus molecular targeted therapies for hepatocellular carcinoma (CHANCE001)[J].Signal Transduct Target Ther,2023,8:58.
[4]Aliseda D,Marti-Cruchaga P,Zozaya G,et al.Liver resection and transplantation following yttrium-90 radioembolization for primary malignant liver tumors:a 15-year single-center experience[J].Cancers (Basel),2023,15:733.
[5]Alsultan AA,Braat AJAT,Smits MLJ,et al.Current status and future direction of hepatic radioembolisation[J].Clin Oncol (R Coll Radiol),2021,33:106-116.
[6]Orth RC,Wallace MJ,Kuo MD,et al.C-arm cone-beam CT:general principles and technical considerations for use in interventional radiology[J].J Vasc Interv Radiol,2009,20:S538-S544..
[7]Jaffray DA,Siewerdsen JH,Wong JW,et al.Flat-panel cone-beam computed tomography for image-guided radiation therapy[J].Int J Radiat Oncol Biol Phys,2002,53:1337-1349.
[8]傅开元,张万林,柳登高,等.应用锥形束CT诊断颞下颌关节骨关节病的探讨[J].中华口腔医学杂志,2007,42:417-420.
[9]杨凯,张学贤,李自恒,等.C臂CT在颅内动脉瘤诊疗中研究进展[J].介入放射学杂志,2022,31:109-112.
[10]Li TF,Ma J,Han XW,et al.Application of high-resolution C-arm CT combined with streak metal artifact removal technology for the stent-assisted embolization of intracranial aneurysms[J].Am J Neuroradiol,2019,40:1752-1758.
[11]中国医师协会介入医师分会临床诊疗指南专委会.中国肝细胞癌经动脉化疗栓塞(TACE)治疗临床实践指南(2023年版)[J].中华医学杂志,2023,103:2674-2694.
[12]Lu J,Zhao M,Arai Y,et al.Clinical practice of transarterial chemoembolization for hepatocellular carcinoma:consensus statement from an international expert panel of International Society of Multidisciplinary Interventional Oncology (ISMIO)[J].Hepatobiliary Surg Nutr,2021,10:661-671.
[13]王为.锥形束CT在放射治疗中的应用[J].中国医学影像技术,2011,27:1074-1077.
[14]Feldkamp LA,Davis LC,Kress JW.Practical cone-beam algorithm[J].J Opt Soc Am A,1984,1:612.
[15]Tacher V,Radaelli A,Lin M,et al.How I do it:cone-beam CT during transarterial chemoembolization for liver cancer[J].Radiology,2015,274:320-334.
[16]Koelblinger C,Schima W,Berger-Kulemann V,et al.C-arm CT during hepatic arteriography tumour-to-liver contrast:intraindividual comparison of three different contrast media application protocols[J].Eur Radiol,2013,23:938-942.
[17]孔铭新,于曰俊,马飞飞,等.锥形束CT双期扫描在肝恶性肿瘤介入治疗中的应用[J].介入放射学杂志,2019,28:38-41.
[18]Pung L,Ahmad M,Mueller K,et al.The role of cone-beam CT in transcatheter arterial chemoembolization for hepatocellular carcinoma:a systematic review and meta-analysis[J].J Vasc Interv Radiol,2017,28:334-341.
[19]Jonczyk M,Collettini F,Schnapauff D,et al.Visibility of hypovascularized liver tumors during intra-arterial therapy using split-bolus single-phase cone beam CT[J].Cardiovasc Intervent Radiol,2019,42:260-267.
[20]Wang C,Wang Q,Chen W,et al.DYNA CT arteriographic evaluation of hepatocellular carcinoma for treatment by trans-catheter arterial chemoembolization[J].Int J Clin Exp Med,2015,8:20548-20555.
[21]Iwazawa J,Ohue S,Mitani T,et al.Identifying feeding arteries during TACE of hepatic tumors:comparison of C-arm CT and digital subtraction angiography[J].Am J Roentgenol,2009,192:1057-1063.
[22]Bannangkoon K,Hongsakul K,Tubtawee T.Impact of cone-beam computed tomography with automated feeder detection software on the survival outcome of patients with hepatocellular carcinoma during treatment with conventional transarterial chemoembolization[J].BMC Gastroenterol,2021,21:419.
[23]Iwazawa J,Ohue S,Hashimoto N,et al.Survival after C-arm CT-assisted chemoembolization of unresectable hepatocellular carcinoma[J].Eur J Radiol,2012,81:3985-3992.
[24]Lee JH,Lee IJ,Kim HB,et al.Efficacy and safety of transarterial chemoembolisation with cone-beam CT in patients with hepatocellular carcinoma within the Milan criteria:a retrospective cohort study[J].Clin Radiol,2019,74:407.e19-407.e28.
[25]Miyayama S,Yamashiro M,Hashimoto M,et al.Comparison of local control in transcatheter arterial chemoembolization of hepatocellular carcinoma ≤6 cm with or without intraprocedural monitoring of the embolized area using cone-beam computed tomography[J].Cardiovasc Intervent Radiol,2014,37:388-395.
[26]Wong SY,Foley S,Cantwell CP,et al.The effects of cone-beam computed tomography imaging guidance on patient radiation exposures in trans-arterial chemoembolisation for hepatocellular carcinoma[J].Radiat Prot Dosimetry,2022,198:441-447.
[27]Hidajat N,Wust P,Felix R,et al.Radiation exposure to patient and staff in hepatic chemoembolization:risk estimation of cancer and deterministic effects[J].Cardiovasc Intervent Radiol,2006,29:791-796.
[28]Yao X,Yan D,Jiang X,et al.Dual-phase cone-beam CT-based navigation imaging significantly enhances tumor detectability and aids superselective transarterial chemoembolization of liver cancer[J].Acad Radiol,2018,25:1031-1037.
[29]Kothary N,Abdelmaksoud MH,Tognolini A,et al.Imaging guidance with C-arm CT:prospective evaluation of its impact on patient radiation exposure during transhepatic arterial chemoembolization[J].J Vasc Interv Radiol,2011,22:1535-1543.
[30]Lucatelli P,De Rubeis G,Basilico F,et al.Sequential dual-phase cone-beam CT is able to intra-procedurally predict the one-month treatment outcome of multi-focal HCC,in course of degradable starch microsphere TACE[J].Radiol Med,2019,124:1212-1219.
[31]Lucatelli P,De Rubeis G,Ginnani Corradini L,et al.Intra-procedural dual phase cone beam computed tomography has a better diagnostic accuracy over pre-procedural MRI and MDCT in detection and characterization of HCC in cirrhotic patients undergoing TACE procedure[J].Eur J Radiol,2020,124:108806.
[32]Cho Y,Lee S,Park SJ.Effectiveness of intraprocedural dual-phase cone-beam computed tomography in detecting hepatocellular carcinoma and improving treatment outcomes following conventional transarterial chemoembolization[J].PLoS One,2021,16:e0245911.
[33]Tacher V,Lin MD,Chao M,et al.Semiautomatic volumetric tumor segmentation for hepatocellular carcinoma:comparison between C-arm cone beam computed tomography and MRI[J].Acad Radiol,2013,20:446-452.
[34]Wang X,Yarmohammadi H,Cao G,et al.Dual phase cone-beam computed tomography in detecting <3 cm hepatocellular carcinomas during transarterial chemoembolization[J].J Cancer Res Ther,2017,13:38-43.
[35]Schernthaner RE,Haroun RR,Duran R,et al.Improved visibility of metastatic disease in the liver during intra-arterial therapy using delayed arterial phase cone-beam CT[J].Cardiovasc Intervent Radiol,2016,39:1429-1437.
[36]Pichon E,Bekes G,Deschamps F,et al.Development and preliminary evaluation of software for planning selective liver embolizations from three-dimensional rotational fluoroscopy imaging[J].Int J Comput Assist Radiol Surg,2008,3:405-412.
[37]Cui Z,Shukla PA,Habibollahi P,et al.A systematic review of automated feeder detection software for locoregional treatment of hepatic tumors[J].Diagn Interv Imaging,2020,101:439-449.
[38]Chiaradia M,Izamis ML,Radaelli A,et al.Sensitivity and reproducibility of automated feeding artery detection software during transarterial chemoembolization of hepatocellular carcinoma[J].J Vasc Interv Radiol,2018,29:425-431.
[39]Miyayama S,Yamashiro M,Nagai K,et al.Efficacy of automated tumor-feeder detection software using cone-beam computed tomography technology in transarterial embolization through extrahepatic collateral vessels for malignant hepatic tumors[J].Hepatol Res,2016,46:166-173.
[40]Miyayama S,Yamashiro M,Ikeda R,et al.Usefulness of virtual parenchymal perfusion software visualizing embolized areas to determine optimal catheter position in superselective conventional transarterial chemoembolization for hepatocellular carcinoma[J].Hepatol Res,2021,51:313-322.
[41]Derbel H,Kobeiter H,Pizaine G,et al.Accuracy of a cone-beam CT virtual parenchymal perfusion algorithm for liver cancer targeting during intra-arterial therapy[J].J Vasc Interv Radiol,2018,29:254-261.e2.
[42]Miyayama S,Yamashiro M,Nagai K,et al.Performance of novel virtual parenchymal perfusion software visualizing embolized areas of transcatheter arterial chemoembolization for hepatocellular carcinoma[J].Hepatol Res,2017,47:446-454.
[43]Kinoshita M,Takechi K,Arai Y,et al.Utility of the virtual liver parenchymal perfusion area using a commercially available workstation in transarterial chemoembolization for hepatocellular carcinoma[J].Cardiovasc Intervent Radiol,2019,42:69-77.
[44]Kim KA,Choi SY,Kim MU,et al.The efficacy of cone-beam CT-based liver perfusion mapping to predict initial response of hepatocellular carcinoma to transarterial chemoembolization[J].J Vasc Interv Radiol,2019,30:358-369.
[45]Choi SY,Kim KA,Choi W,et al.Usefulness of cone-beam CT-based liver perfusion mapping for evaluating the response of hepatocellular carcinoma to conventional transarterial chem-oembolization[J].J Clin Med,2021,10:713.
[46]Li Z,Jiao D,Si G,et al.Making timely remedial measures after TACE based on the results of cone-beam CT liver perfusion[J].Int J Hyperthermia,2021,38:428-436.
[47]Tsai YC,Shih JH,Hwang HE,et al.Early prediction of 1-year tumor response of hepatocellular carcinoma with lipiodol deposition pattern through post-embolization cone-beam computed tomography during conventional transarterial chemoembolization[J].Eur Radiol,2021,31:7464-7475.
[48]Fronda M,Mistretta F,Calandri M,et al.The role of immediate post-procedural cone-beam computed tomography (CBCT) in predicting the early radiologic response of hepatocellular carcinoma (HCC) nodules to drug-eluting bead transarterial chemoembolization (DEB-TACE)[J].J Clin Med,2022,11:7089.
[49]Stein SI,Soliman M,Sparapani J,et al.Conventional hepatic volumetry May Lead to inaccurate segmental yttrium-90 radiation dosimetry[J].Cardiovasc Intervent Radiol,2021,44:1973-1985.
[50]O′Connor PJ,Pasik SD,van der Bom IM,et al.Feasibility of yttrium-90 radioembolization dose calculation utilizing intra-procedural open trajectory cone beam CT[J].Cardiovasc Intervent Radiol,2020,43:295-301.
[51]Schernthaner RE,Chapiro J,Sahu S,et al.Feasibility of a modified cone-beam CT rotation trajectory to improve liver periphery visualization during transarterial chemoembolization[J].Radiology,2015,277:833-841.
[52]Hatamikia S,Biguri A,Herl G,et al.Source-detector trajectory optimization in cone-beam computed tomography:a comprehensive review on Today′s state-of-the-art[J].Phys Med Biol,2022,67:16TR03.
[53]Kwon LM,Hwang JS,Lee YS,et al.A motion artifact correction algorithm for cone-beam CT in patients with hepatic malignancies treated with transarterial chemoembolization[J].J Vasc Interv Radiol,2022,33:1367-1374.
[54]Becker LS,Dewald CLA,von Falck C,et al.Effectuality study of a 3D motion correction algorithm in C-arm CTs of severely impaired image quality during transarterial chemoembolization[J].Cancer Imaging,2022,22:37.
[55]de Baere T,Ronot M,Chung JW,et al.Initiative on superselective conventional transarterial chemoembolization results (INSPIRE)[J].Cardiovasc Intervent Radiol,2022,45:1430-1440.

备注/Memo

备注/Memo:
(收稿日期:2023-12-24)
(本文编辑:新宇)
更新日期/Last Update: 2024-12-18