[1]蒋春雨,王建波. 血流导向装置在颅内动脉瘤介入治疗中的应用[J].介入放射学杂志,2014,(03):267-271.
 JIANG Chun? yu,WANG jian? bo.. The application of flow diverter stent in treating intracranial aneurysms[J].journal interventional radiology,2014,(03):267-271.
点击复制

 血流导向装置在颅内动脉瘤介入治疗中的应用 ()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2014年03期
页码:
267-271
栏目:
综述
出版日期:
2014-03-25

文章信息/Info

Title:
 The application of flow diverter stent in treating intracranial aneurysms
作者:
 蒋春雨 王建波
Author(s):
JIANG Chun?蛳 yu WANG jian?蛳 bo.
  Department of Radiology, Soochow University, Suzhou, Jiangsu Province 215000, China
关键词:
【关键词】 颅内动脉瘤 血流导向装置 血流动力学 治疗
文献标志码:
A
摘要:
 【摘要】 介入治疗在颅内动脉瘤的治疗中占有不可替代的地位,且随着介入器械和材料的不断更新,其所占比重越来越大。近年来,随着载瘤动脉重建概念的提出,一种新型的血流导向装置应运而生,引起广大临床医生的极大兴趣。血流导向装置(flow diverter stent,FDS)是一种低网孔率支架,将其置于载瘤动脉内可实现对载瘤动脉的血流动力学重建,诱发动脉瘤内自发性血栓形成,最终达到治愈动脉瘤的目的。现对血流导向装置综述如下。

参考文献/References:

 [1] Zacharia BE, Hickman ZL, Grobelny BT, et al. Epidemiology of aneurysmal subarachnoid hemorrhage[J]. Neurosurg Clin N Am, 2010, 21: 221 ?蛳 233.
[2] Li MH, Leng B, Li YD, et al. Comparative study of covered stent with coil embolization in the treatment of cranial internal carotid artery aneurysm: a nonrandomized prospective trial[J]. Eur Radiol, 2010, 20: 2732 ?蛳 2739.
[3] Choi DS, Kim MC, Lee SK, et al. Clinical and angiographic long?蛳 term follow?蛳 up of completely coiled intracranial aneurysms using endovascular technique[J]. J Neurosurg, 2010, 112: 575 ?蛳 581.
[4] Liou TM, Li YC. Effects of stent porosity on hemodynamics in a sidewall aneurysm model[J]. J Biomech, 2008, 41: 1174 ?蛳 1183.
[5] Guglielmi G. The beginning and the evolution of the endovascular treatment of intracranial aneurysms: from the first catheterization of brain arteries to the new stents[J]. J Neurointerv Surg, 2009, 1: 53 ?蛳 55.
[6] Lieber BB, Stancampiano AP, Wakhloo AK. Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity[J]. Ann Biomed Eng, 1997, 25: 460 ?蛳 469.
[7] Rhee K, Han MH, Cha SH. Changes of flow characteristics by stenting in aneurysm models: influence of aneurysm geometry and stent porosity[J]. Ann Biomed Eng, 2002, 30: 894 ?蛳 904.
[8] Lylyk P, Miranda C, Ceratto R, et al. Curative endovascular Reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience[J]. Neurosurgery, 2009, 64: 632 ?蛳 642.
[9] McAuliffe W, Wenderoth JD. Immediate and midterm results following treatment of recently ruptured intracranial aneurysms with the Pipeline embolization device[J]. Am J Neuroradiol, 2012, 33: 487 ?蛳 493.
[10] Byrne JV, Beltechi R, Yarnold JA, et al. Early experience in the treatment of intra ?蛳 cranial aneurysms by endovascular flow diversion: a multicentre prospective study[J]. PLoS One, 2010, 5: pii: e12492.
[11] Kulcsár Z, Ernemann U, Wetzel SG, et al. High?蛳 profile flow diverter(silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators[J]. Stroke, 2010, 41: 1690 ?蛳 1696.
[12] 杨鹏飞, 刘建民, 黄清海, 等. 新型血流导向装置Tubridge治疗颅内动脉瘤的初步经验[J]. 介入放射学杂志, 2011, 20: 357 ?蛳 362.
[13] De Vries J, Boogaarts J, Van Norden A, et al. New Generation of flow diverter (surpass) for unruptured intracranial aneurysms: a prospective single?蛳 center study in 37 patients[J]. Stroke, 2013, 44: 1567 ?蛳 1577.
[14] Berge J, Biondi A, Machi P, et al. Flow?蛳 diverter silk stent for the treatment of intracranial aneurysms: 1?蛳 year follow?蛳 up in a multicenter study[J]. Am J Neuroradiol, 2012, 33: 1150 ?蛳 1155.
[15] Brinjikji W, Murad MH, Lanzino G, et al. Endovascular treatment of intracranial aneurysms with flow diverters: a meta?蛳 analysis[J]. Stroke, 2013, 44: 442 ?蛳 447.
[16] Lubicz B, Collignon L, Raphaeli G, et al. Flow?蛳 diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms[J]. Stroke, 2010, 41: 2247 ?蛳 2253.
[17] Briganti F, Napoli M, Tortora F, et al. Italian multicenter experience with flow?蛳 diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications—a retrospective data analysis[J]. Neuroradiology, 2012, 54: 1145 ?蛳 1152.
[18] Cruz JP, Chow M, O’Kelly C, et al. Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms[J]. Am J Neuroradiol, 2012, 33: 603 ?蛳 608.
[19] Darsaut TE, Rayner ?蛳 Hartley E, Makoyeva A, et al. Aneurysm rupture after endovascular flow diversion: the possible role of persistent flows through the transition zone associated with device deformation[J]. Interv Neuroradiol, 2013, 19: 180 ?蛳 185.
[20] Claren?觭on F, Di Maria F, Biondi A, et al. Distant and delayed (> 7 days) hemorrhage after treatment by flow?蛳 diverter stents in intracranial aneurysms: a rare but potentially serious complication[J]. Am J Neuroradiol, 2013, 34: 81 ?蛳 82.
[21] Pierot L. Flow diverter stents in the treatment of intracranial aneurysms: Where are we?[J]. J Neuroradiol, 2011, 38: 40 ?蛳 46.
[22] T?覿htinen OI, Manninen HI, Vanninen RL, et al. The silk flow?蛳 diverting stent in the endovascular treatment of complex intracranial aneurysms: technical aspects and midterm results in 24 consecutive patients[J]. Neurosurgery, 2012, 70: 617 ?蛳 623.
[23] Nelson PK, Lylyk P, Szikora I, et al. The pipeline embolization device for the intracranial treatment of aneurysms trial[J]. Am J Neuroradiol, 2011, 32: 34 ?蛳 40.
[24] Fischer S, Vajda Z, Aguilar Perez M, et al. Pipeline embolization device(PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections[J]. Neuroradiology, 2012, 54: 369 ?蛳 382.
[25] Pereira VM, Bonnefous O, Ouared R, et al. A DSA?蛳 based method using contrast?蛳 motion estimation for the assessment of the intra?蛳 aneurysmal flow changes induced by flow?蛳 diverter stents[J]. Am J Neuroradiol, 2013, 34: 808 ?蛳 815.
[26] Shankar JS, Vandorpe R, Pickett G, et al. Silk flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis[J]. J Neurointerv Surg, 2013: 页码范围缺失.
[27] 刘建民, 王奎重, 黄清海, 等. 低孔率血流导向装置治疗兔囊状宽颈动脉瘤及对分支的影响[J]. 中华神经外科杂志, 2010, 26: 984 ?蛳 987.
[28] 张 星, 黄清海, 施 洋, 等. 支架孔率对脑动脉瘤血流动力学影响的三维数值模拟研究[J]. 介入放射学杂志, 2009, 18: 213 ?蛳 216.
[29] Phillips TJ, Wenderoth JD, Phatouros CC, et al. Safety of the pipeline embolization device in treatment of posterior circulation aneurysms[J]. Am J Neuroradiol, 2012, 33: 1225 ?蛳 1231.
[30] Siddiqui AH, Abla AA, Kan P, et al. Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms: Clinical article[J]. J Neurosurg, 2012, 116: 1258 ?蛳 1266.
[31] Kallmes DF, Ding YH, Dai D, et al. A second?蛳 generation, endoluminal, flow?蛳 disrupting device for treatment of saccular aneurysms[J]. Am J Neuroradiol, 2009, 30: 1153 ?蛳 1158.

相似文献/References:

[1]杨鹏飞,刘建民,黄清海,等.新型血流导向装置Tubridge治疗颅内动脉瘤的初步经验[J].介入放射学杂志,2011,(05):357.
 YANG Pengfei,LIU Jianmin,HUANG Qinghai,et al.The use of novel flow diverting device Tubridge for the treatment of intracranial aneurysms: initial experience[J].journal interventional radiology,2011,(03):357.
[2]邢 鸣,杨鹏飞,黄清海,等.支架治疗颈内动脉分叉部宽颈动脉瘤[J].介入放射学杂志,2012,(02):92.
 XING Ming,YANG Peng-fei,HUANG Qing-hai,et al.Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation[J].journal interventional radiology,2012,(03):92.
[3]黄海东,顾建文,杨春敏,等.Enterprise支架辅助弹簧圈栓塞治疗前交通宽颈动脉瘤的临床研究[J].介入放射学杂志,2012,(07):536.
 HUANG Hai- dong,GU Jian- wen,YANG Chun-min,et al. Enterprise stent- assisted coil embolization for wide?蛳 necked anterior communicating artery aneurysms: a clinical study[J].journal interventional radiology,2012,(03):536.
[4]陆 靖,李永东,李明华,等. 时间飞越法磁共振血管造影对蛛网膜下腔出血诊断和治疗的临床价值[J].介入放射学杂志,2012,(09):711.
 LU Jing,LI Yong- dong,LI Ming- hua,et al. The clinical value of time- of-flight MRA in diagnosing and treating subarachnoid haemorrhage[J].journal interventional radiology,2012,(03):711.
[5]田红岸,赵 卫,易根发. 动脉灌注替罗非班在处理颅内动脉瘤栓塞术中急性血栓栓塞的研究[J].介入放射学杂志,2012,(09):718.
 TIAN Hong- an,ZHAO Wei,YI Geng-fa.. Application of intra- arterial infusion of tirofiban in dealing with acute thromboembolism occurred during embolization therapy for intracranial aneurysms: a preliminary study[J].journal interventional radiology,2012,(03):718.
[6]陈 状,李 林,王伟民,等. SolitaireAB支架结合弹簧圈治疗颅内宽颈动脉瘤的初步经验[J].介入放射学杂志,2013,(06):447.
 CHEN Zhuang,LI Lin,WANG Wei? min,et al. SolitaireAB stent- assisted coiling of intracranial wide- necked aneurysms: preliminary experience[J].journal interventional radiology,2013,(03):447.
[7]田红岸,赵 卫,易根发. 颅内动脉瘤内支架辅助治疗的并发症分析[J].介入放射学杂志,2012,(11):885.
 TIAN Hong- an,ZHAO Wei,YI Geng- fa.. Endovascular stent- assited management for the treatment of intracranial aneurysms: an analysis of complications[J].journal interventional radiology,2012,(03):885.
[8]温宏峰,赵春霞,李继来,等. 双微导管技术栓塞颅内宽颈不规则动脉瘤[J].介入放射学杂志,2012,(11):890.
 WEN Hong- feng,ZHAO Cun- xia,LI Ji- lai,et al. Double microcatheter technique for detachable coil treatment of wide?蛳 necked and irregular intracranial aneurysms[J].journal interventional radiology,2012,(03):890.
[9]崔艳峰,徐 浩,祖茂衡,等. Solitaire AB支架在辅助栓塞颅内宽颈动脉瘤中的临床应用[J].介入放射学杂志,2013,(08):617.
 CUl Yan? feng,XU Hao,ZU Mao? heng,et al. Clinical application of Solitaire AB stent in assisting coiling embolization for intracranial wide?蛳 necked aneurysms[J].journal interventional radiology,2013,(03):617.
[10]郄福忠,马光涛,王玖飞,等.大脑中动脉分叉部动脉瘤的血管内介入治疗[J].介入放射学杂志,2014,(08):655.
 QIE Fu zhong,MA Guang tao,WANG Jiu fei,et al.Endovascular interventional embolization for the treatment of aneurysms located at the bifurcation of middle cerebral artery[J].journal interventional radiology,2014,(03):655.
[11]李 航,李天晓,白卫星,等.颅内巨大动脉瘤血流导向装置治疗术后再破裂出血1例[J].介入放射学杂志,2017,(06):507.
 LI Hang,LI Tianxiao,BAI Weixing,et al.Rupture with bleeding of giant intracranial aneurysm occurring after flow diversion therapy: report of one case[J].journal interventional radiology,2017,(03):507.
[12]张学贤,杨 凯,赵 卫,等.血流导向装置治疗颅内动脉瘤后覆盖分支通畅性研究进展[J].介入放射学杂志,2021,30(10):1061.
 ZHANG Xuexian,YANG Kai,ZHAO Wei,et al.The patency of covered side branches of intracranial aneurysms after flow-diverter treatment: recent progress in research[J].journal interventional radiology,2021,30(03):1061.
[13]徐李刚,万 军,张 磊,等.国产Tubridge血流导向装置治疗中小型颅内动脉瘤的短期疗效及安全性分析[J].介入放射学杂志,2023,32(05):421.
 XU Ligang,WAN Jun,ZHANG Lei,et al.Domestic Tubridge flow diverter for the treatment of small and medium-sized intracranial aneurysms: analysis of its short-term efficacy and safety[J].journal interventional radiology,2023,32(03):421.
[14]朱 涛,李 晓,陈 振,等.Tubridge血流导向装置治疗破裂颅内动脉瘤临床分析 [J].介入放射学杂志,2024,33(02):165.
 ZHU Tao,LI Xiao,CHEN Zhen,et al.Tubridge flow diverter for the treatment of ruptured intracranial aneurysms: clinical analysis of its safety and efficacy[J].journal interventional radiology,2024,33(03):165.

备注/Memo

备注/Memo:
 (收稿日期:2013-08-05)
更新日期/Last Update: