[1]叶 成,朱小旭,王贾楠,等.双向双LOOP技术在超时间窗Aegisy下腔静脉滤器回收中的应用[J].介入放射学杂志,2025,34(10):1113-1116.[doi:10.3969/j.issn.1008-794X.2025.10.014]
 YE Cheng,ZHU Xiaoxu,WANG Jianan,et al.Clinical application of bidirectional dualloop technology in retrieving Aegisy inferior vena cava filters beyond the time window[J].J Intervent Med,2025,34(10):1113-1116.[doi:10.3969/j.issn.1008-794X.2025.10.014]
点击复制

双向双LOOP技术在超时间窗Aegisy下腔静脉滤器回收中的应用()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
34
期数:
2025年10
页码:
1113-1116
栏目:
临床研究
出版日期:
2025-10-25

文章信息/Info

Title:
Clinical application of bidirectional dualloop technology in retrieving Aegisy inferior vena cava filters beyond the time window
文章编号:
1008-794X(2025)-010-1113-04
作者:
叶 成 朱小旭 王贾楠 齐县伟 辛 颖 邢 程 张宪亮
466000 河南周口 周口市中心医院介入科
Author(s):
YE ChengZHU XiaoxuWANG JiananQI XianweiXIN YingXING ChengZHANG Xianliang.
Department of Interventional Radiology,Zhoukou Municipal Central Hospital,Zhoukou,Henan Province 466000,China
关键词:
Aegisy下腔静脉滤器 双向双LOOP
DOI:
10.3969/j.issn.1008-794X.2025.10.014
文献标志码:
B
摘要:
目的 总结双向双LOOP技术在腔静脉滤器回收中的应用。方法 纳入2016年1月至2023年11月在周口市中心医院住院期间因下肢深静脉血栓形成合并肺栓塞、下肢深静脉血栓形成、行抽栓术下腔静脉滤器置入患者12例。应用标准方法、导丝剥离、球囊扩张、单向单LOOP和单向双LOOP技术等方法回收超时间窗Aegisy下腔静脉滤器,因回收困难转为使用双向双LOOP技术。滤器留置30~365 d,平均105 d。结果 11例患者的滤器被完整取出,造影显示下腔静脉通畅,未见对比剂外溢,平均手术时间126 min。1例患者滤器未被取出,终身抗凝。未发生手术相关并发症。结论 双向双LOOP技术安全、有效,值得推广应用。

参考文献/References:

[1] 中国微循环学会周围血管疾病专业委员会下肢静脉腔内治疗专业委员会.急性下肢深静脉血栓形成腔内治疗专家共识[J].血管与腔内血管外科杂志,2023,9:513-519.
[2]中华医学会呼吸病学分会肺栓塞与肺血管病学组,中国医师协会呼吸医师分会肺栓塞与肺血管病工作组,全国肺栓塞与肺血管病防治协作组,等.慢性血栓栓塞性肺动脉高压诊断与治疗指南(2024版)[J].中华医学杂志,2024,104:2200-2221.
[3]中国医师协会介入医师分会,中华医学会放射学分会介入专业委员会,中国静脉介入联盟.下腔静脉滤器置入术和取出术规范的专家共识(第2版)[J].中华医学杂志,2020,100:2092-2101.
[4]杨 红,葛卫宁,张敬涛,等.改良wire-loop技术在严重倾斜下腔静脉滤器回收中的应用效果[J].中华外科杂志,2022,60:1063-1068.
[5]胡 杰,乔茂林,田琴琴,等.Loop技术矫转法对复杂性下腔静脉滤器取出的技巧及应用效果分析[J].介入放射学杂志,2024,33:289-294.
[6]Serrano E,Vila-Trias E,Zarco F,et al.Difficult withdrawal of an inferior vena cava filter:Technical considerations and associated variables[J].Radiologia(Engl Ed),2023,65:230-238.
[7]Clements W,Moriarty HK,Paul E,et al.Stratification of pre-procedure risk factors associated with difficult-to-remove inferior vena cava(IVC)filters:a 6-year retrospective analysis at a tertiary center[J].Cardiovasc Intervent Radiol,2020,43:238-245.
[8]Li H,Jia Z,Chen X,et al.Efficacy and retrievability of aegisy vena cava filter:a single center experience in 213 patients[J].Ann Vasc Surg,2016,36:226-230.
[9]Feng H,Li C,Feng H.Numerical simulation and in vitro experimental study of thrombus capture efficiency of a new retrievable vena cava filter[J].Comput Methods Biomech Biomed Engin,2023,26:2034-2046.
[10]Du X,Li C,Qian A,et al.Bidirectional pull-back technique for retrieval of strut-embedded cylinder-shaped filters in inferior vena cava[J].Med Sci Monit,2017,23:2796-2804.
[11]Li X,Haddadin I,McLennan G,et al.Inferior vena cava filter-comprehensive overview of current indications,techniques,complications and retrieval rates[J].Vasa,2020,49:449-462.
(收稿日期:2024-10-05)
(本文编辑:新 宇)

备注/Memo

备注/Memo:
通信作者: 叶 成 E-mail:920022708@qq.com
更新日期/Last Update: 2025-10-25