[1]陆发承,王家平,邢艺苑,等.Ovation覆膜支架系统介绍及临床应用[J].介入放射学杂志,2016,(05):456-459.
 LU Fa- cheng,WANG Jia- ping,XING Yi- yuan,et al.Ovation covered- stent system: introduction and clinical application[J].journal interventional radiology,2016,(05):456-459.
点击复制

Ovation覆膜支架系统介绍及临床应用 ()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2016年05期
页码:
456-459
栏目:
综 述
出版日期:
2016-05-25

文章信息/Info

Title:
Ovation covered- stent system: introduction and clinical application
作者:
陆发承 王家平 邢艺苑 万珊杉
Author(s):
LU Fa- cheng WANG Jia- ping XING Yi- yuan WAN Shan- shan
Department of Radiology, Second Affiliated Hospital of Kunming Medical University, Kunming, Yunnan Province 650101, China
关键词:
【关键词】 Ovation覆膜支架腔内修复术腹主动脉瘤
文献标志码:
A
摘要:
【摘要】 腔内成形术已经成为具有适应证的腹主动脉瘤的首选治疗方式,但由于器材和患者本身血管解剖的限制,许多患者不能行腔内修复术。而采用模组理念设计的全新ovation覆膜支架系统,在近期的临床研究中表现出了良好的安全性和有效性,使得对具有复杂的血管解剖的患者行腔内修复术成为可能。本文就Ovation覆膜支架系统及其目前在临床上的应用情况进行一综述。

参考文献/References:

[1] 禹纪红, 黄连军, 蒋世良, 等. 腔内隔绝术治疗高风险腹主动脉瘤[J]. 介入放射学杂志, 2010, 19: 287- 290.
[2] 廖登辉, 叶财盛, 李松奇, 等. 覆膜支架治疗12例假性动脉瘤的体会[J]. 介入放射学杂志, 2012, 21: 374- 376.
[3] Propper BW, Abularrage CJ. Long- term safety and efficacy of endovascular abdominal aortic aneurysm repair[J]. Vasc Health Risk Manag, 2013, 9: 135- 141.
[4] 王精兵, 程永德. 重视覆膜支架在外周血管病中的应用[J]. 介入放射学杂志, 2007, 16: 577- 579.
[5] 刘 暴, 刘昌伟. 腹主动脉瘤腔内治疗的适应证——我们是不是走得太远?[J]. 中国微创外科杂志, 2013, 13: 772- 773, 784.
[6] 王豪夫, 王曰伟, 李 君, 等. 腹主动脉瘤腔内修复术22例围手术期处理回顾性总结[J]. 介入放射学杂志, 2010, 19: 858- 861.
[7] 熊 斌, 梁惠民, 郑传胜, 等. 覆膜支架在外周动脉瘤及动脉夹层治疗中的应用[J]. 介入放射学杂志, 2013, 22: 31- 35.
[8] Krajcer Z. TriVascular Ovation?誖: it’s role in solving current endograft deficiencies.[J]. J Cardiovasc Surg (Torino), 2015, 56: 325- 329.
[9] Yao JS, Eskandari MK, Parodia J. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms, 1991: two decades later[J]. Ann Vasc Surg, 2012, 26: 895- 905.
[10] 王深明, 姚 陈. 腹主动脉瘤血管腔内治疗的现状与进展[J]. 中国普外基础与临床杂志, 2014, 21: 657- 659.
[11] Moulakakis KG, Dalainas I, Kakisis J, et al. Current knowledge on EVAR with the ultra- low profile Ovation abdominal stent- graft system[J]. J Cardiovasc Surg (Torino), 2012, 53: 427- 432.
[12] Georgakarakos E, Ioannou CV, Trellopoulos G, et al. Immediate change in suprarenal neck angulation after endovascular aneurysm repair: comparison of the Ovation stent- graft inflatable sealing rings to a conventional self- expanding stent- graft[J]. J Endovasc Ther, 2015, 22: 613- 619.
[13] Massmann A, Serracino- Inglott F, Buecker A. Endovascular aortic repair with the chimney technique using the ultra low- profile Ovation stent- graft for juxtarenal aneurysms having small iliac access vessels[J]. Cardiovasc Intervent Radiol, 2014, 37: 488- 492.
[14] Mangialardi N, Ronchey S, Kasemi H, et al. Percutaneous endovascular aneurysm repair with the ultra- low profile Ovation abdominal stent- graft system[J]. J Cardiovasc Surg (Torino), 2013, 54: 581- 587.
[15] Carrafiello G, Ierardi A, Piffaretti G, et al. Treatment of abdominal aortic aneurysm with a new type of polymer- filled low profile device[J]. Int J Surg, 2013, 11: S24- S29.
[16] Nano G, Mazzaccaro D, Stegher S, et al. Early experience with Ovation endograft system in abdominal aortic disease[J]. J Cardio- thorac Surg, 2014, 9: 48.
[17] Mehta M, Valdes FE, Nolte T, et al. One- year outcomes from an international study of the Ovation Abdominal Stent Graft System for endovascular aneurysm repair[J]. J Vasc Surg, 2014, 59: 65- 73.
[18] Ioannou CV, Kontopodis N, Kehagias E, et al. Endovascular aneurysm repair with the Ovation TriVascular Stent- Graft System utilizing a predominantly percutaneous approach under local anaesthesia[J]. Br J Radiol, 2015, 88: 20140735.
[19] Gandini R, Del Giudice C, Abrignani S, et al. Inexplicable late type ia endoleak associated with the low- profile Ovation endograft in a patient with favorable neck anatomy: treatment with transcaval coil embolization[J]. J Endovasc Ther, 2015, 22: 426- 430.
[20] Georgakarakos E, Schoretsanitis N, Souftas VD, et al. Emergent conversion of the Ovation StentGraft System to aortouniiliac modification via occlusion of a unilateral internal iliac artery with a stentgraft as a bailout solution[J]. Vascular, 2015, 23: 440- 443.
[21] Kehagias E, Kontopodis N, Tsetis D, et al. Bifurcated aortoiliac endograft limb occlusion during deployment and its bailout conversion using the external iliac artery to internal iliac artery endograft technique[J]. Ann Vasc Surg, 2015, 29: 1029- 1034.
[22] Sfyroeras GS, Moulakakis KG, Antonopoulos CN, et al. Anaphylactic reaction during implantation of the Ovation StentGraft system in a patient with abdominal aortic aneurysm[J]. J Endovasc Ther, 2015, 22: 620- 622.
[23] Demanget N, Duprey A, Badel P, et al. Finite element analysis of the mechanical performances of 8 marketed aortic stent- grafts[J]. J Endovasc Ther, 2013, 20: 523- 535.
[24] Demanget N, Avril S, Badel P, et al. Computational comparison of the bending behavior of aortic stent- grafts[J]. J Mech Behav Biomed Mater, 2012, 5: 272- 282.
[25] Verhoeven BA, Waasdorp EJ, Gorrepati ML, et al. Long- term results of talent endografts for endovascular abdominal aortic aneurysm repair[J]. J Vasc Surg, 2011, 53: 293- 298.
[26] Sweet MP, Fillinger MF, Morrison TM, et al. The influence of gender and aortic aneurysm size on eligibility for endovascular abdominal aortic aneurysm repair[J]. J Vasc Surg, 2011, 54: 931- 937.
[27] Georgiadis GS, Charalampidis D, Georgakarakos EI, et al. Open conversion after endovascular aortic aneurysm repair with the ovation prime endograft[J]. Int J Artif Organs, 2014, 37: 177- 181.
[28] Ioannou CV, Kontopodis N, Metaxa E, et al. Graft inflow stenosis induced by the inflatable ring fixation mechanism of the Ovation stent- graft system: hemodynamic and clinical implications[J]. J Endovasc Ther, 2014, 21: 829- 838.

相似文献/References:

[1]徐克,吴瑕,陈冉,等.腔内修复术治疗DeBakeyⅢ型主动脉夹层动脉瘤中远期疗效评价[J].介入放射学杂志,2008,(08):567.
 XU Ke,WU Xia,CHEN Ran,et al.Evaluation of the effect on endovascular repair of DeBakey III aortic dissection:middle-long term follow-up result s[J].journal interventional radiology,2008,(05):567.
[2]王丽娟,孙桂芳,刘训强,等.Stanford B型主动脉夹层腔内修复术后早期死亡患者术前多层螺旋CT特征分析[J].介入放射学杂志,2020,29(04):357.
 WANG Lijuan,SUN Guifang,LIU Xunqiang,et al.Analysis of preoperative MSCT features in early death patients with Stanford type B aortic dissection after endovascular repair[J].journal interventional radiology,2020,29(05):357.
[3]杨呈伟,薛玉国,关济,等.腹主动脉瘤支架植入术后Ⅱ型内漏并迟发瘤体破裂1例 [J].介入放射学杂志,2020,29(01):114.
 YANG Chengwei,XUE Yuguo,GUAN Ji,et al. TypeⅡendoleak and delayed aneurysm rupture occurring after endovascular repair of abdominal aortic aneurysm with stent implantation: report of one case[J].journal interventional radiology,2020,29(05):114.
[4]艾克白尔 江艾尼瓦尔,冯睿,冯家烜,等.胸腹主动脉瘤微创腔内治疗进展[J].介入放射学杂志,2020,29(01):109.
 ANIWAER Aikebaierjiang,FENG Rui,FENG Jiaxuan,et al.Recent advances in minimally-invasive endovascular repair of thoracoabdominal aortic aneurysms[J].journal interventional radiology,2020,29(05):109.

备注/Memo

备注/Memo:
(收稿日期:2015-10-21)
(本文编辑:俞瑞纲)
更新日期/Last Update: 2016-05-16