[1]任建庄,张萌帆,张 凯,等.Wallstent双支架重叠技术治疗复杂内脏动脉瘤五例[J].介入放射学杂志,2014,(12):1036-1040.
 REN Jian zhuang,ZHANG Meng fan,ZHANG Kai,et al.Safety and efficacy of dual Wallstent stenting in managing complicated visceral aneurysms: initial experience in 5 cases[J].journal interventional radiology,2014,(12):1036-1040.
点击复制

Wallstent双支架重叠技术治疗复杂内脏动脉瘤五例 ()

PDF下载中关闭

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2014年12期
页码:
1036-1040
栏目:
血管介入
出版日期:
2014-12-25

文章信息/Info

Title:
Safety and efficacy of dual Wallstent stenting in managing complicated visceral aneurysms: initial experience in 5 cases
作者:
任建庄;  张萌帆;  张 凯;  黄郭灏;  段旭华;  李腾飞;  韩新巍
Author(s):
REN Jian zhuang;  ZHANG Meng fan;  ZHANG Kai;  HUANG Guo hao;  DUAN Xu hua;  LI Teng fei;  HAN Xin wei.
Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
关键词:
【关键词】 内脏动脉瘤;  Wallstent;  介入放射学
文献标志码:
A
摘要:
【摘要】 目的 初步评价Wallstent双支架重叠技术治疗复杂内脏动脉瘤的安全性和疗效。方法 回顾性分析2012年3月至2013年11月连续收治的5例内脏动脉瘤患者,包括1例脾动脉起始部梭形动脉瘤、1例脾动脉中段囊状动脉瘤、1例腹腔干囊状动脉瘤、1例肝总动脉囊状动脉瘤、1例肠系膜上动脉宽颈动脉瘤。瘤体平均直径(23.0 ± 8.7)mm。5例内脏动脉瘤均行Wallstent双支架重叠植入治疗,术后给予抗血小板药物治疗,术后6个月、1年、2年行CTA(computed tomographic angiography)检查,观察动脉瘤闭塞情况,支架、载瘤动脉和侧支血管和穿支动脉通畅情况。结果 5例患者支架均成功植入,术后30 d内1例腹腔干动脉瘤患者出现轻微腹痛,给予止痛、扩血管药物等对症处理后1周后症状消失,余患者无其他手术相关并发症发生。5例患者术后随访6 ~ 24个月(平均13个月),动脉瘤均较前均缩小或消失。其中1例肝总动脉囊状动脉瘤患者术后6个月CTA显示支架内轻度狭窄(狭窄 < 25%)同时合并部分穿支动脉闭塞,但无明显临床症状,余患者支架、侧支血管和穿支动脉均通畅。结论 Wallstent双支架重叠技术植入治疗复杂内脏动脉瘤具有较好的技术成功率和疗效,侧支血管和穿支动脉长期通畅率较高。

参考文献/References:

 [1] Balderi A, Antonietti A, Ferro L, et al. Endovascular treatment of visceral artery aneurysms and pseudoaneurysms: our experience[J]. Radiol Med, 2012, 117: 815 830.
[2] Koganemaru M, Abe T, Nonoshita M, et al. Follow up of true visceral artery aneurysm after coil embolization by three dimensional contrast enhanced Mr angiography[J]. Diagn Interv Radiol, 2014, 20: 129 135.
[3] 杨鹏飞, 刘建民, 黄清海, 等. 新型血流导向装置Tubridge治疗颅内动脉瘤的初步经验[J]. 介入放射学杂志, 2011, 20: 357 362.
[4] Ruffino MA, Rabbia C, Italian Cardiatis Registry Investigators Group. Endovascular repair of peripheral and visceral aneurysms with the Cardiatis multilayer flow modulator: one year results from the Italian Multicenter Registry[J]. J Endovasc Ther, 2012, 19: 599 610.
[5] Zhang L, Yin CP, Li HY, et al. Multiple overlapping bare stents for endovascular visceral aneurysm repair: a potential alternative endovascular strategy to multilayer stents[J]. Ann Vasc Surg, 2013, 27: 606 612.
[6] Cordova AC, Sumpio BE. Visceral artery aneurysms and Pseudoaneurysms Should they all be managed by endovascular techniques?[J]. Ann Vasc Dis, 2013, 6: 687 693.
[7] ACC/AHA 2005 Practice Guidelines for the Management of Patients With Peripheral Arterial Disease (Lower Extremity, Renal, Mesenteric, and Abdominal Aortic)[J]. Circulation, 2006, 113(11): e463 e465.
[8] Mohan IV, Stephen MS. Peripheral arterial aneurysms: open or endovascular surgery?[J]. Prog Cardiovasc Dis, 2013, 56: 36 56.
[9] Sakakibara K, Shindo S, Matsumoto M, et al. Splenic artery aneurysm of the hepatosplenomesenteric trunk[J]. Ann Vasc Dis, 2013, 6: 730 733.
[10] Kulkarni CB, Moorthy S, Pullara SK, et al. Endovascular treatment of aneurysm of splenic artery arising from splenomesentric trunk using stent graft[J]. Korean J Radiol, 2013, 14: 931 934.
[11] Cochennec F, Riga CV, Allaire E, et al. Contemporary management of splanchnic and renal artery aneurysms: results of endovascular compared with open surgery from two European vascular centers[J]. Eur J Vasc Endovasc Surg, 2011, 42: 340 346.
[12] Tulsyan N, Kashyap VS, Greenberg RK, et al. The endovascular management of visceral artery aneurysms and pseudoaneurysms[J]. J Vasc Surg, 2007, 45: 276 283; discussion 283.
[13] Ikeda O, Nakasone Y, Tamura Y, et al. Endovascular management of visceral artery pseudoaneurysms: transcatheter coil embolization using the isolation technique[J]. Cardiovasc Intervent Radiol, 2010, 33: 1128 1134.
[14] 朱悦琦, 李明华, 方 淳, 等. 应用Willis覆膜支架治疗脑池段动脉瘤的临床对照研究和长期随访结果[J]. 介入放射学杂志, 2010, 19: 275 280.
[15] Sfyroeras GS, Dalainas I, Giannakopoulos TG, et al. Flow diverting stents for the treatment of arterial aneurysms[J]. J Vasc Surg, 2012, 56: 839 846.
[16] Augsburger L, Farhat M, Reymond P, et al. Effect of flow diverter porosity on intraaneurysmal blood flow[J]. Klin Neuroradiol, 2009, 19: 204 214.
[17] Myouchin K, Takayama K, Taoka T, et al. Carotid wallstent placement difficulties encountered in carotid artery stenting[J]. Springerplus, 2013, 2: 468.
[18] Müller Hülsbeck S, Sch?覿fer PJ, Charalambous N, et al. Comparison of carotid stents: an in vitro experiment focusing on stent design[J]. J Endovasc Ther, 2009, 16: 168 177.
[19] Pierce DS, Rosero EB, Modrall JG, et al. Open cell versus closed cell stent design differences in blood flow velocities after carotid stenting[J]. J Vasc Surg, 2009, 49: 602 606; discussion 606.
[20] Canton G, Levy DI, Lasheras JC, et al. Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms[J]. J Neurosurg, 2005, 103: 891 902.
[21] Jeon P, Kim BM, Kim DI, et al. Reconstructive endovascular treatment of fusiform or ultrawide neck circumferential aneurysms with multiple overlapping enterprise stents and coiling[J]. AJNR, 2012, 33: 965 971.

相似文献/References:

[1]张 伟,张曦彤,田玉龙,等.不锈钢弹簧圈填塞治疗内脏动脉瘤8例[J].介入放射学杂志,2016,(04):308.
 ZHANG Wei,ZHANG Xi- tong,TIAN Yu- long,et al.Embolization with stainless coil packing for visceral artery aneurysms: initial experience in 8 cases[J].journal interventional radiology,2016,(12):308.

备注/Memo

备注/Memo:
(收稿日期:2014-06-09)
(本文编辑:李 欣)
更新日期/Last Update: 2014-12-24